Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions: The Tri-LEAD Study.

Storozhenko Tatyana, Russo Giulio, Vanderheyden Marc, De Backer Ole, Rosseel Michael, Hermans Hadewich, Vanduynhoven Philippe, De Potter Tom, Van Camp Guy, Adamo Marianna, Pancaldi Edoardo, Estevez-Loureiro Rodrigo, Sievert Horst, Piayda Kerstin, Mylotte Darren, Lochy Stijn, Hausleiter Joerg, Stolz Lukas, Nestelberger Thomas, Wagener Max, Patterson Tiffany, Wilcox Joshua, Swaans Martin J, Timmers Leo, Vrijkorte Martijn, Taramasso Maurizio, Rosseel Liesbeth

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tricuspid transcatheter edge-to-edge repair (T-TEER) is an important treatment option for symptomatic severe tricuspid valve regurgitation. Interaction with a preexisting right ventricular (RV) pacing lead can result in clinically significant RV lead dysfunction over time.

OBJECTIVES

The goal of this study was to evaluate the 2-year safety and function of preexisting RV leads after T-TEER.

METHODS

The Tri-LEAD (Tricuspid Right Ventricular lead entrapment in transcatheter tricuspid interventions) study was a retrospective multicenter international registry of 146 patients who underwent T-TEER with an RV lead in situ from 2015 to 2023. Primary outcome was RV lead dysfunction after T-TEER at 2 years (defined as change in RV lead function, dislodgement, or fracture) and need for intervention due to RV lead dysfunction or cardiac complication.

RESULTS

Mean patient age was 78.1 ± 8.6 years, and 54% were male. Over a median follow-up of 557 days (Q1-Q3: 278-966 days), 10 patients (6.8%) had an impedance change >200 Ω and 2 patients (1.4%) had a threshold change ≥1 V, with no observed cases of RV lead fracture, dislodgement, cardiac structure perforation, or pacemaker-related re-interventions. T-TEER was not associated with an increased risk of the composite safety endpoint (adjusted SHR: 1.39; 95% CI: 0.64 to 3.02; P = 0.41). Over time, changes in RV lead sensing (-0.53 mV/year; 95% CI: -1.15 to 0.08; P = 0.094), impedance (-2.4 Ω/year; 95% CI: -15.4 to 10.6; P = 0.72), and threshold (-0.011 V/year; 95% CI: -0.052 to 0.031; P = 0.62) were minimal and not clinically significant.

CONCLUSIONS

T-TEER has no detrimental impact on the performance of transvenous RV leads in the short term or midterm.

Для цитирования: Storozhenko Tatyana, Russo Giulio, Vanderheyden Marc, De Backer Ole, Rosseel Michael, Hermans Hadewich, Vanduynhoven Philippe, De Potter Tom, Van Camp Guy, Adamo Marianna, Pancaldi Edoardo, Estevez-Loureiro Rodrigo, Sievert Horst, Piayda Kerstin, Mylotte Darren, Lochy Stijn, Hausleiter Joerg, Stolz Lukas, Nestelberger Thomas, Wagener Max, Patterson Tiffany, Wilcox Joshua, Swaans Martin J, Timmers Leo, Vrijkorte Martijn, Taramasso Maurizio, Rosseel Liesbeth. Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions: The Tri-LEAD Study.. JACC. Clinical electrophysiology. 2025. DOI: 10.1016/j.jacep.2025.11.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.