MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2005.04.008

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2005

Transcatheter placement of a low-profile biodegradable pulmonary valve made of small intestinal submucosa: a long-term study in a swine model.

Ruiz Carlos E, Iemura Motofumi, Medie Sibyl, Varga Peter, Van Alstine William G, Mack Susan, Deligio Anna, Fearnot Neal, Beier Ulf H, Pavcnik Dusan, Hijazi Ziyad M, Kiupel Matti

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

We sought to investigate a placement of a percutaneous low-profile prosthetic valve constructed of small intestinal submucosa in the pulmonary position in a swine model.

METHODS

Twelve female farm pigs were stented at the native pulmonary valve to induce pulmonary insufficiency. Once right ventricular dilation occurred, the small intestinal submucosa valve was implanted. The pigs were followed up with transthoracic echocardiographic Doppler scanning. One animal died of heart failure before valve replacement. Animals were euthanized at 1 day, 1 month, 3 months, 6 months, and 12 months after valve implantation.

RESULTS

The small intestinal submucosa pulmonary valve showed effective reversal of pulmonary regurgitation. There were no misplacements during deployment. There were no embolizations. One-year echocardiographic follow-up showed minimal regurgitation and no stenosis for a valve/vessel ratio of 0.78 or greater. Histologic examination demonstrated intensive remodeling of the small intestinal submucosal valve. Within 1 month, the surface was covered by endothelium, and fibroblasts invaded the interior. Over the following months, the small intestinal submucosal valve remodeled without apparent graft rejection.

CONCLUSION

The small intestinal submucosa valve has the potential for graft longevity without the need for anticoagulation or immunosuppression. Histologic remodeling of the valve tissue provides a replacement capable of resembling a native valve that can be placed percutaneously with low-profile delivery systems.

Для цитирования: Ruiz Carlos E, Iemura Motofumi, Medie Sibyl, Varga Peter, Van Alstine William G, Mack Susan, Deligio Anna, Fearnot Neal, Beier Ulf H, Pavcnik Dusan, Hijazi Ziyad M, Kiupel Matti. Transcatheter placement of a low-profile biodegradable pulmonary valve made of small intestinal submucosa: a long-term study in a swine model.. The Journal of thoracic and cardiovascular surgery. 2005. DOI: 10.1016/j.jtcvs.2005.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.