MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archopht.1996.01100140141005

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 1996

Intraocular pressure-raising potential of 1.0% rimexolone in patients responding to corticosteroids.

Leibowitz H M, Bartlett J D, Rich R, McQuirter H, Stewart R, Assil K

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To compare the intraocular pressure (IOP) elevating potential of 1.0% rimexolone and 0.1% fluorometholone alcohol ophthalmic suspensions in patients known to have responded to corticosteroids.

DESIGN

In a double-masked, randomized, single-eye, crossover protocol, corticosteroid responsiveness initially was verified in 40 asymptomatic known steroid responders by challenge with either 0.1% dexamethasone sodium phosphate or 1.0% prednisolone acetate for up to 6 weeks. After a 1-month medication washout, subjects randomly received either rimexolone or fluorometholone for 6 weeks. Medications were again discontinued for 1 month, and subjects then received the alternate drug for 6 weeks.

RESULTS

There was no significant difference between rimexolone and fluorometholone in the number of subjects demonstrating a 10-mm Hg increase in IOP or in the mean number of weeks required to achieve a 10-mm Hg response. Responses occurred in significantly more subjects receiving dexamethasone sodium phosphate (P = .001) or prednisolone acetate (P < .001) and in a significantly shorter interval than in subjects receiving rimexolone.

CONCLUSIONS

Rimexolone has a low IOP-elevating potential, comparable to that of fluorometholone and less than that of dexamethasone sodium phosphate and prednisolone acetate.

Для цитирования: Leibowitz H M, Bartlett J D, Rich R, McQuirter H, Stewart R, Assil K. Intraocular pressure-raising potential of 1.0% rimexolone in patients responding to corticosteroids.. Archives of ophthalmology (Chicago, Ill. : 1960). 1996. DOI: 10.1001/archopht.1996.01100140141005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.