Long-term desensitization for ABO-incompatible living related kidney transplantation recipients with high refractory and rebound anti-blood type antibody: case report.

Nishimura Hiroaki, Yamada Yasutoshi, Hisano Satoshi, Mitsuke Akihiko, Tatarano Syuichi, Gotanda Takenari, Hayami Hiroshi, Nakagawa Masayuki, Enokida Hideki

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

ABO-incompatible living related kidney transplantation (ABO-iLKT) has increased the possibilities for kidney transplantation in patients with end stage renal disease. Due to advancements in immunosuppressive agents and the identification of immunological conditions following ABO-iLKT, this transplantation technique has achieved the same success rate as ABO-compatible LKT. However, some patients continue to generate anti-blood type antibodies, despite conventional immunosuppressant treatment.

CASE PRESENTATION: A 60-year-old man was referred to our hospital for kidney transplantation. The proposed transplant was ABO incompatible, from a donor with blood-type A to a recipient with blood-type O. The recipient's anti-A blood-type IgG antibody titer was measured at 4096-fold dilution. Following desensitization therapy, including mycophenolate mofetil (MMF) 750 mg/day for 3 months, intravenous Rituximab 200 mg, and two sessions of double filtration plasmapheresis, the anti-A blood-type IgG antibody titer decreased to only 516-fold dilution and did not meet our target of less than 128-fold dilution. MMF was thus continued for an additional 4 months and four additional sessions of plasmapheresis were undertaken. Following these interventions, antibody titers decreased to 128-fold dilution and ABO-iLKT was performed. Following transplant, antibody-mediated rejection was not observed and renal function was preserved. However, a post-operative renal biopsy 1.5 months later showed evidence of T-cell-mediated rejection IB. The patient was treated with steroids, with no increase in serum creatinine.

CONCLUSION

Our findings suggest that the long-term single MMF desensitization therapy could be a suitable option for ABO-iLKT with high refractory and rebound anti-blood type antibody. Further studies are required to establish the optimal immunosuppression regimen to control B cell- mediated immunity in ABO-iLKT.

Для цитирования: Nishimura Hiroaki, Yamada Yasutoshi, Hisano Satoshi, Mitsuke Akihiko, Tatarano Syuichi, Gotanda Takenari, Hayami Hiroshi, Nakagawa Masayuki, Enokida Hideki. Long-term desensitization for ABO-incompatible living related kidney transplantation recipients with high refractory and rebound anti-blood type antibody: case report.. BMC nephrology. 2018. DOI: 10.1186/s12882-018-1053-8.