m+Medelevator.RU
← Поиск публикаций
Clinical therapeutics · 2025

Exposure to Budesonide, Glycopyrronium, and Formoterol With a Next-Generation Propellant Does Not Exceed Exposure With Hydrofluoroalkane-134a Propellant When Administered Via Pressurized Metered-Dose Inhaler With a Spacer.

СтатьяКлиническое исследование I фазыРандомизированное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pandya Hitesh, Patel Mehul, Gillen Michael, Reddy Jitendar, Bednarczyk Artur, Kokot Marek, Tan Yubo, Heijer Maria, Andersson Magdalena, Petullo David, Jassal Mandeep

Аннотация

PURPOSE: Hydrofluoroalkane-134a (HFA-134a), the propellant in the marketed budesonide/glycopyrronium/formoterol fumarate dihydrate (BGF) formulation, has a global warming potential (GWP) that falls above environmental regulation thresholds and therefore will be phased out. With global efforts to minimize carbon emissions, the hydrofluoroolefin-1234ze (HFO-1234ze) propellant, with a >99% lower GWP than HFA-134a, is in development for pressurized metered-dose inhalers (pMDIs). Spacers support drug delivery in patients with poor pMDI inhalation technique, but it is unknown if BGF exposure with HFO-1234ze exceeds that observed with HFA-134a when using a spacer.

METHODS: This Phase I study assessed systemic BGF component exposure with HFO-1234ze versus HFA-134a when using a spacer, and for HFO-1234ze with and without a spacer. Participants (N = 42) were randomized to BGF with HFA-134a with a spacer (reference), HFO-1234ze with a spacer (test), and HFO-1234ze without a spacer (descriptive treatment) over 3 treatment periods in 1 of 6 sequences. As spacer devices help to increase exposure, the upper limit of the 90% confidence interval (CI) of geometric mean ratios (GMRs) was of interest, and bioequivalence was not included as a study objective.

FINDINGS: Analyses demonstrated the upper 90% CI of the GMRs for maximum observed plasma concentration (Cmax) and area under the plasma concentration curve from time zero to the time of the last quantifiable concentration (AUClast) were <125% for all BGF components for HFO-1234ze versus HFA-134a when using a spacer, indicating exposure with HFO-1234ze did not exceed exposure with HFA-134a. Additionally, Cmax was increased for all BGF components with HFO-1234ze when using versus not using a spacer, with the largest increases observed among participants with the lowest exposure when not using a spacer, likely due to poor inhalation technique. No new safety findings, and no deaths or serious adverse events, occurred during the study.

IMPLICATIONS: These findings provide evidence that may help to support the future use of HFO-1234ze propellant in BGF pMDIs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты