[Artificial intelligence for diagnosis of vertebral compression fractures using a morphometric analysis model, based on convolutional neural networks].
Аннотация
BACKGROUND
Pathological low-energy (LE) vertebral compression fractures (VFs) are common complications of osteoporosis and predictors of subsequent LE fractures. In 84% of cases, VFs are not reported on chest CT (CCT), which calls for the development of an artificial intelligence-based (AI) assistant that would help radiology specialists to improve the diagnosis of osteoporosis complications and prevent new LE fractures.
AIMS: To develop an AI model for automated diagnosis of compression fractures of the thoracic spine based on chest CT images.
MATERIALS AND
METHODS
Between September 2019 and May 2020 the authors performed a retrospective sampling study of ССТ images. The 160 of results were selected and anonymized. The data was labeled by seven readers. Using the morphometric analysis, the investigators received the following metric data: ventral, medial and dorsal dimensions. This was followed by a semiquantitative assessment of VFs degree. The data was used to develop the Comprise-G AI mode based on CNN, which subsequently measured the size of the vertebral bodies and then calculates the compression degree. The model was evaluated with the ROC curve analysis and by calculating sensitivity and specificity values.
RESULTS
Formed data consist of 160 patients (a training group - 100 patients; a test group - 60 patients). The total of 2,066 vertebrae was annotated. When detecting Grade 2 and 3 maximum VFs in patients the Comprise-G model demonstrated sensitivity - 90,7%, specificity - 90,7%, AUC ROC - 0.974 on the 5-FOLD cross-validation data of the training dataset; on the test data - sensitivity - 83,2%, specificity - 90,0%, AUC ROC - 0.956; in vertebrae demonstrated sensitivity - 91,5%, specificity - 95,2%, AUC ROC - 0.981 on the cross-validation data; for the test data sensitivity - 79,3%, specificity - 98,7%, AUC ROC - 0.978.
CONCLUSIONS
The Comprise-G model demonstrated high diagnostic capabilities in detecting the VFs on CCT images and can be recommended for further validation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.