MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3892/etm.2023.11955

Медицинская библиотека · Experimental and therapeutic medicine · 2023

A biomechanical analysis of the effect of hydroxyapatite augmentation for trochanteric femoral fractures.

Usami Takuya, Takada Naoya, Iwata Hidetoshi, Sakai Hiroaki, Hattori Yusuke, Sekiya Isato, Ueki Yoshino, Nagaya Yuko, Murakami Hideki, Kuroyanagi Gen

СтатьяПеревод в очереди

Аннотация

Hydroxyapatite (HA) augments are used to treat trochanteric femoral fractures. However, the efficacy of HA augmentation has not been fully described in trochanteric femoral fracture surgery. In total, 85 patients were enrolled in the present study; all had trochanteric femoral fractures between January 2016 and October 2020, 45 with HA (HA group) and 40 without HA (N group). The intraoperative lag screw insertion torque was directly measured and the amount of lag screw telescoping with and without HA augmentation after surgery was analyzed. Maximum lag screw insertion torque (max-torque), bone mineral density in the opposite femoral neck (n-BMD), tip apex distance (TAD) of the lag screw, radiographic findings including fracture union, the amounts of lag screw telescoping and occurrence of complications were evaluated. A total of 12 patients were excluded if they were aged under 60 years old, had ipsilateral surgery and disorders in the hip joint, TAD of the lag screw ≥26 mm on postoperative radiographs and had measurement errors. A total of 73 fractures could be analyzed: HA group (n=36) and N group (n=37). Max-torque/n-BMD ratios were higher in the HA group compared with in the N group (7.23±2.71 vs. 5.93±1.91 g/cm2·N·m; P=0.04). The amounts of lag screw telescoping in the HA group were smaller compared with the N group (1.41±2.00 vs. 2.58±2.34; P=0.05). Evaluation of screw insertion torque showed maximum screw insertion torque correlated well with n-BMD in both groups, HA (R=0.57; P<0.01) and N group (R=0.64; P<0.01). No correlation was found between maximum screw insertion torque and TAD in both groups, HA (R=-0.10; P=0.62) and N group (R=0.02; P=0.93). All fractures were radiographically united without any complications. These results support the effectiveness of HA augmentation, indicating higher resistance against rotational instability and reduced lag screw telescoping in trochanteric femoral fracture treatment.

Для цитирования: Usami Takuya, Takada Naoya, Iwata Hidetoshi, Sakai Hiroaki, Hattori Yusuke, Sekiya Isato, Ueki Yoshino, Nagaya Yuko, Murakami Hideki, Kuroyanagi Gen. A biomechanical analysis of the effect of hydroxyapatite augmentation for trochanteric femoral fractures.. Experimental and therapeutic medicine. 2023. DOI: 10.3892/etm.2023.11955.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.