MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/tlcr-2025-439

Медицинская библиотека · Translational lung cancer research · 2025

Performance comparison of four published lung cancer prediction models applied to a cohort from the National Lung Screening Trial.

Schroeder Kimberly E, Knoernschild Kevin, Averill Sarah L, Hoffman Richard M, Sieren Jessica C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Mathematical prediction models (MPMs) based on clinical and radiologist-assessed features have been developed to assist with lung cancer risk assessment for imaging-detected lung nodules. However, MPMs were developed using different datasets, thresholds, and feature sets, making it difficult to cross-compare the published performance metrics and determine prospective performance stability. The aim of this study is to utilize a large lung cancer screening cohort with identified pulmonary nodules to compare the performance of four MPMs, at a standardized sensitivity value, to reduce the false positive rate for lung cancer screening exams.

METHODS

This retrospective study utilized low-dose computed tomography (LDCT) identified lung nodules from the National Lung Screening Trial (NLST) to evaluate four MPMs [Mayo Clinic (MC), Veterans Affairs (VA), Peking University (PU), and Brock University (BU)]. For cross-comparison, a small NLST sub-cohort (n=270) was used to determine a calibrated decision threshold for each model, targeting a sensitivity for detecting lung cancer of 95%. Performance was evaluated using area under the receiver-operating-characteristic curve (AUC-ROC), area under the precision-recall curve (AUC-PR), sensitivity, and specificity. The calibrated threshold applied to the remaining NLST cohort (n=1,083) was used to demonstrate the stability of performance metrics.

RESULTS

A total of 1,353 patients [mean ± standard deviation (SD) age, 62.3±5.2 years; 746 male] were included, of which 122 (9.0%) had a malignant nodule. At the target sensitivity of 95%, the highest testing specificity (correctly identified benigns) was seen in the BU and MC models (55% and 52%, respectively), compared to the VA (45%) and the PU (16%). The AUC-ROCs for BU (83%), MC (83%), PU (76%), and VA (77%) suggest high-moderate performance, while AUC-PR more accurately reflects that all the models have sub-optimal precision (27-33%).

CONCLUSIONS

Tuning calibration thresholds of existing MPM aids in performance comparison and stability for application in the lung cancer screening setting. However, targeting high sensitivity (95%), the achievable specificity of the MPMs is low (16-55%), which may limit clinical utility.

Для цитирования: Schroeder Kimberly E, Knoernschild Kevin, Averill Sarah L, Hoffman Richard M, Sieren Jessica C. Performance comparison of four published lung cancer prediction models applied to a cohort from the National Lung Screening Trial.. Translational lung cancer research. 2025. DOI: 10.21037/tlcr-2025-439.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.