DOI 10.1007/s11306-026-02435-3
Identification of salivary lipid biomarkers for noninvasive diagnosis of reflux esophagitis via UHPLC-MS-based lipidomics.
Аннотация
INTRODUCTION
Reflux esophagitis (RE) is a common upper gastrointestinal disorder, and its diagnosis currently relies primarily on invasive endoscopic examination. The lack of reliable non-invasive biomarkers substantially limits early detection and large-scale screening. Saliva represents a promising biofluid for metabolomics research, as it can reflect metabolic alterations associated with upper gastrointestinal pathology.
OBJECTIVES
This study aimed to identify potential salivary lipid biomarkers associated with RE, and to develop a non-invasive diagnostic model using metabolomics and lipidomics.
METHODS
Saliva samples from patients clinically diagnosed with RE and healthy controls were analyzed. The analysis included a discovery cohort (n = 144) and an independent validation cohort (n = 146). Differential metabolites were screened using the untargeted metabolomics approach of ultra-high performance liquid chromatography-mass spectrometry (UHPLC-MS), and then quantitative verification was conducted using targeted lipidomics. Multivariate statistical analysis, random forest algorithms, and receiver operating characteristic (ROC) analysis were applied.
RESULTS
Untargeted metabolomics revealed significant metabolic differences between RE patients and healthy controls, with marked enrichment of sphingolipid and glycerophospholipid metabolism. Targeted lipidomics identified six consistently dysregulated salivary lipids: DAG (18:1_18:2), S-1-P, PE (P-16:0_18:1), DAG (16:0_18:2), DAG (18:1_18:1), and DAG (16:0_18:1). A multimetabolite model based on these lipids effectively distinguished RE patients from healthy controls, achieving an AUC of 99.45% in the discovery cohort and 97.17% in the validation cohort.
CONCLUSION
This study identified a salivary lipid signature associated with RE and supports the potential of this lipidomic approach as a non-invasive method to distinguish RE from healthy controls.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.