Peregrine system infusion catheter for neurolytic renal denervation in hypertension: an overview of its safety and efficacy.

Janas Adam, Wojakowski Wojciech

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Resistant hypertension (HTN), despite the tremendous advances in pharmacotherapy, is a major global problem. Transcatheter renal denervation (RDN) could be a pertinent strategy for resistant HTN and patients with poor pharmacotherapy adherence. Nonetheless, the adoption of energy-based RDN in clinical practice is slow and alternative approaches are needed.

AREAS COVERED: The review focuses on the assessment of the Peregrine System Infusion Catheters. The system is designed for chemically mediated transcatheter RDN by the infusion publications on the Peregrine system. The theoretical assumptions for chemically mediated RDN, design of the system, data from preclinical and clinical studies, and further perspectives are discussed.

EXPERT OPINION: Peregrine System Infusion Catheters are the only catheter on the market designed for chemically mediated RDN by the infusion of the neurolytic agent. Chemical neurolysis more efficiently destroys nerves around the renal artery in comparison to energy-based catheters, due to deeper tissue penetration and circumferential distribution resulting in a wider range of effective nerve injury. Chemically mediated RDN by the infusion of the neurolytic agent (alcohol) has an excellent safety profile as confirmed in initial clinical trials which also suggested high efficacy. Currently, there is an ongoing phase III sham-control study. Other possible applications of this technology include clinical settings like heart failure or atrial fibrillation.

Для цитирования: Janas Adam, Wojakowski Wojciech. Peregrine system infusion catheter for neurolytic renal denervation in hypertension: an overview of its safety and efficacy.. Expert review of medical devices. 2023. DOI: 10.1080/17434440.2023.2183838.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.