Effectiveness of C5 or C6-Cz assembly in predicting immediate post operative facial nerve deficit.
Аннотация
BACKGROUND
Intraoperative neurophysiology monitoring (IOM) is a valuable tool in cerebellopontine angle (CPA) surgeries posing risk to the cranial nerves. Transcranial electrical stimulation (TES) for cranial nerves has been performed in the last 7 years, for obtaining the facial nerve motor evoked potential (MEP), using either C3/C4-Cz or C3-C4 (or inverse) stimulating points, which have been correlated with facial nerve functional outcome.
METHOD: Intraoperative surgical and electrophysiological findings were documented prospectively. Patient files were reviewed for clinical data. We studied 23 patients undergoing CPA tumor resection using C5 or C6-Cz montage for TES, and were able to determine the correlation between facial nerve functional outcome and the amplitude drop of facial MEP above 50 %. Patients were evaluated for immediate facial nerve outcome and 6 months after the surgery. Follow-up was performed by structured telephone interviews with local physicians.
RESULTS
The sensibility of the studied parameters was 92.8 % for amplitude drop of facial nerve MEP, with positive predictive value of 81.2 %. The absence of changes during IOM has shown a negative predictive value of 100 %.
CONCLUSION
In this series, the used montage was effective in predicting new facial deficit.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.