DOI 10.1056/nejmoa2401807

Медицинская библиотека · The New England journal of medicine · 2024

A Modular Communicative Leadless Pacing-Defibrillator System.

Knops Reinoud E, Lloyd Michael S, Roberts Paul R, Wright David J, Boersma Lucas V A, Doshi Rahul, Friedman Paul A, Neuzil Petr, Blomström-Lundqvist Carina, Bongiorni Maria Grazia, Burke Martin C, Gras Daniel, Kutalek Steven P, Amin Anish K, Fu Eugene Y, Epstein Laurence M, Tolosana Jose Maria, Callahan Thomas D, Aasbo Johan D, Augostini Ralph, Manyam Harish, Nair Devi G, Mondésert Blandine, Su Wilber W, Pepper Chris, Miller Marc A, Grammes Jon, Saleh Karim, Marquie Christelle, Merchant Faisal M, Cha Yong-Mei, Cunnington Colin, Frankel David S, West Julie, Matznick Elizabeth, Swackhamer Bryan, Brisben Amy J, Weinstock Jonathan, Stein Kenneth M, Reddy Vivek Y, Mont Lluis, MODULAR ATP Investigators

СтатьяМногоцентровое исследованиеКлиническое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown.

METHODS

We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%).

RESULTS

We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure.

CONCLUSIONS

The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

Для цитирования: Knops Reinoud E, Lloyd Michael S, Roberts Paul R, Wright David J, Boersma Lucas V A, Doshi Rahul, Friedman Paul A, Neuzil Petr, Blomström-Lundqvist Carina, Bongiorni Maria Grazia, Burke Martin C, Gras Daniel, Kutalek Steven P, Amin Anish K, Fu Eugene Y, Epstein Laurence M, Tolosana Jose Maria, Callahan Thomas D, Aasbo Johan D, Augostini Ralph, Manyam Harish, Nair Devi G, Mondésert Blandine, Su Wilber W, Pepper Chris, Miller Marc A, Grammes Jon, Saleh Karim, Marquie Christelle, Merchant Faisal M, Cha Yong-Mei, Cunnington Colin, Frankel David S, West Julie, Matznick Elizabeth, Swackhamer Bryan, Brisben Amy J, Weinstock Jonathan, Stein Kenneth M, Reddy Vivek Y, Mont Lluis, MODULAR ATP Investigators. A Modular Communicative Leadless Pacing-Defibrillator System.. The New England journal of medicine. 2024. DOI: 10.1056/nejmoa2401807.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.