m-EASIX (better than EASIX) predicts severe CAR T-cell toxicities, worse overall survival, and discriminates cytokine release syndrome from sepsis.

Moreno-Castaño Ana Belén, Fernández Sara, Brillembourg Helena, Iraola Gontzal, Moreno David F, Ventosa-Capell Helena, Martinez-Sanchez Julia, De Moner Blanca, Molina Patricia, Ramos Alex, Palomo Marta, Gómez-Ramírez Pilar, Ortiz-Maldonado Valentín, Martínez-Cibrián Nuria, Delgado Julio, Oliver-Caldés Aina, Fernández de Larrea Carlos, Salas María Queralt, Urbano Álvaro, Téllez Adrián, Nicolás José María, Juan Manel, González-Navarro Azucena, Penack Olaf, Escolar Gines, Carreras Enric, Fernández-Avilés Francesc, Castro Pedro, Diaz-Ricart Maribel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cytokine Release Syndrome (CRS) and Immune Effector Cell-Associated Neurotoxicity Syndrome (ICANS) are life-threatening complications that often arise after CAR T-cell immunotherapy. Endothelial dysfunction is believed to play a central role in their development, leading to the interest in biomarker-based tools for diagnosis and differentiating these toxicities from sepsis. This study aimed to evaluate the Endothelial Activation Stress Index (EASIX) and its modified version (m-EASIX, which replaces creatinine with C-reactive protein [CRP] (mg/dL)) as early predictors of severe CRS and ICANS, as well as tools to distinguish CRS from sepsis.

METHODS

One hundred and nineteen patients treated with CAR T-cell therapy for CD19-positive hematologic malignancies (n=94) or multiple myeloma (n=23) were included. EASIX and m-EASIX scores were measured at various time points: before CAR T-cell infusion, 24-48 hours post-infusion, at CRS or ICANS onset, and after treatment for each toxicity. A comparator group of 129 sepsis patients, including 86 with hematologic malignancies, was also analyzed.

RESULTS

Both EASIX and m-EASIX correlated with biomarkers of endotheliopathy, with m-EASIX showing stronger predictive power for severe toxicities and ICU admission. Higher EASIX and m-EASIX values at early time points were associated with worse overall survival (OS). Furthermore, m-EASIX accurately distinguished CRS from sepsis at symptom onset.

CONCLUSIONS

m-EASIX is a practical and accessible tool for the early prediction of severe CAR T-cell-related toxicities, risk stratification, and differential diagnosis from sepsis, offering potential to guide clinical decision-making and early intervention.

Для цитирования: Moreno-Castaño Ana Belén, Fernández Sara, Brillembourg Helena, Iraola Gontzal, Moreno David F, Ventosa-Capell Helena, Martinez-Sanchez Julia, De Moner Blanca, Molina Patricia, Ramos Alex, Palomo Marta, Gómez-Ramírez Pilar, Ortiz-Maldonado Valentín, Martínez-Cibrián Nuria, Delgado Julio, Oliver-Caldés Aina, Fernández de Larrea Carlos, Salas María Queralt, Urbano Álvaro, Téllez Adrián, Nicolás José María, Juan Manel, González-Navarro Azucena, Penack Olaf, Escolar Gines, Carreras Enric, Fernández-Avilés Francesc, Castro Pedro, Diaz-Ricart Maribel. m-EASIX (better than EASIX) predicts severe CAR T-cell toxicities, worse overall survival, and discriminates cytokine release syndrome from sepsis.. Frontiers in immunology. 2026. DOI: 10.3389/fimmu.2025.1664788.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.