MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d5tb01157d

Медицинская библиотека · Journal of materials chemistry. B · 2025

A redox-responsive NIR fluorescent nanoprobe for tumor microenvironment-activated surgical navigation with submillimeter precision.

Sun Jian, Ye Jintao, Tang Wenwei, Yu Bin, Gao Yong, Wang Shengli, Zhang Haijuan

СтатьяПеревод в очереди

Аннотация

Surgical precision in tumor resection critically relies on real-time intraoperative imaging, yet conventional probes face limitations in specificity and spatiotemporal control. Here, we present a tumor microenvironment (TME)-activated near-infrared (NIR) fluorescent nanoprobe (DNS-DYE/PEG-NI) that integrates dual responsiveness to hypoxia and glutathione (GSH) for submillimeter-level surgical navigation. The system comprises a GSH-activatable NIR fluorophore (λex/em = 679/730 nm) quenched by 2,4-dinitrobenzenesulfonyl (DNS) moieties and hypoxia-sensitive amphiphilic PEG-NI micelles. Upon tumor accumulation via the enhanced permeability and retention (EPR) effect, a hypoxic TME triggers micelle disassembly through nitroimidazole (NI) reduction, releasing DNS-DYE. Subsequent GSH cleavage restores fluorescence via intramolecular charge transfer (ICT) recovery, achieving a 12.3-fold tumor-to-normal tissue signal ratio and >90% reduction in off-target activation compared to non-responsive controls. Systematic validation demonstrates: (1) dose-dependent fluorescence recovery (35-fold intensity increase at 10 mM GSH); (2) hypoxia-driven micelle destabilization (800% hydrodynamic diameter expansion); (3) sustained colloidal stability (12.9% size variation over 15 days); and (4) low cytotoxicity (cell viability >90% at 125 μg mL-1). In vivo studies reveal precise tumor delineation within 12 h post-injection, enabling real-time resection of submillimeter lesions. By coupling TME-specific activation with prolonged tumor retention, this dual-responsive nanoprobe advances fluorescence-guided surgery toward precision oncology, reducing positive margin rates from 70% to <5% in preclinical models.

Для цитирования: Sun Jian, Ye Jintao, Tang Wenwei, Yu Bin, Gao Yong, Wang Shengli, Zhang Haijuan. A redox-responsive NIR fluorescent nanoprobe for tumor microenvironment-activated surgical navigation with submillimeter precision.. Journal of materials chemistry. B. 2025. DOI: 10.1039/d5tb01157d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.