DOI 10.1177/15266028221141023

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2022

Severe Tortuosity of the Distal Descending Thoracic Aorta Affects the Accuracy of Distal Deployment During a Thoracic Endovascular Aortic Repair.

Sato Tomohiro, Banno Hiroshi, Ikeda Shuta, Kawai Yohei, Tsuruoka Takuya, Sugimoto Masayuki, Niimi Kiyoaki, Kodama Akio, Komori Kimihiro

СтатьяПеревод в очереди

Аннотация

PURPOSE: An accurate distal deployment is essential for successful thoracic endovascular aortic repair (TEVAR) of a paradiaphragmatic aortic aneurysm. This study aimed to investigate the anatomical and intraoperative factors that affect the accuracy of distal deployment during TEVAR.

METHODS

We conducted a retrospective review of preoperative and postoperative computed tomography scans of 426 patients undergoing TEVAR at our institution between October 2008 and May 2021, of which the stent-graft was attempted to be deployed just above the celiac axis or the superior mesenteric artery in 56 patients. Based on the anatomical factors related to the malposition (deployed >10 mm away from the target vessel) and the greater curve to the straight-line ratio (G/S ratio), the patients were categorized as severe tortuosity (n=21) and mild tortuosity (n=35) groups to compare the operative and clinical outcomes.

RESULT: Stent-graft malpositioning occurred in 21 cases. Among all anatomical variables, only the G/S ratio was significantly larger in the malpositioned cases (p=0.049). A cutoff G/S ratio value of 1.15 was determined using the receiver operating curve analysis. In the severe tortuosity group, the distal end of the stent-graft was significantly farther (median: 10.0 [interquartile range (IQR): 2.5-19.5] mm vs 3.0 [0-8.0] mm; p=0.015) from the target vessel, and the tilt angle of the stent-graft's distal edge was larger (median: 21.4 [IQR: 15.8-24.5] vs 9.5 [5.5-12.5] degree; p<0.01) than that in the mild tortuosity group. Both groups were comparable for the incidence of a primary type Ib endoleak (p=0.454), a secondary type Ib endoleak (p=1.0), and the rate of distal reintervention (p=0.276).

CONCLUSION

Severe tortuosity in the distal descending thoracic aorta is associated with a malpositioned and tilted distal end of the stent-graft.

CLINICAL IMPACT: Thoracic endovascular aortic repair (TEVAR) for paradiaphragmatic thoracic aortic aneurysms requires accurate distal landing. In this paper, a retrospective CT analysis revealed that the greater curve to the straight-line ratio (G/S ratio) was associated to affects the malposition of the stent graft, defined as being deployed more than 10 mm away from the target vessel. Further, a comparative analysis based on the G/S ratio demonstrated that severe aortic tortuosity was associated with a more distal and tilted deployment of the stent graft.

Для цитирования: Sato Tomohiro, Banno Hiroshi, Ikeda Shuta, Kawai Yohei, Tsuruoka Takuya, Sugimoto Masayuki, Niimi Kiyoaki, Kodama Akio, Komori Kimihiro. Severe Tortuosity of the Distal Descending Thoracic Aorta Affects the Accuracy of Distal Deployment During a Thoracic Endovascular Aortic Repair.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2022. DOI: 10.1177/15266028221141023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.