BACKGROUND

We sought to assess the effects of percutaneous atrial septal defect (ASD) closure on blood biomarker levels that possibly reflect reverse cardiac remodeling. Therefore, this study investigated temporal changes in six blood biomarkers following percutaneous ASD closure in adults.

METHODS

In this prospective observational cohort study, adults with ASD type II scheduled for percutaneous closure were included (2012-2016). NT-proBNP, high-sensitive troponin-T (hs-TnT), high-sensitive C-reactive protein (hs-CRP), red blood cell distribution width (RDW), growth differentiation factor-15 (GDF-15) and galectin-3 were measured one day prior to ASD closure and one day, three months and one year post ASD closure, and changes were evaluated using paired T-tests. Echocardiographic measurements were obtained.

RESULTS

Fifty patients were included (median age 50 years, 62% women, 32% NYHA II). At baseline, biomarker levels were elevated in a substantial number of patients; NT-proBNP n = 22 (45%), hs-TnT n = 6 (13%) hs-CRP n = 19 (40%), galectin-3 n = 5 (11%) and GDF n = 10 (23%). One day after ASD closure, significant increases of hs-TnT (median change (Δ) = 12 ng/L), hs-CRP (Δ = 1.9 mg/L), GDF-15(Δ = 129 pg/mL) and RDW (Δ = 0.1%) were observed, and a decrease in galectin-3 (Δ = -1.0 ng/mL). Consequently, 92% had at least one abnormal biomarker directly after closure. At three months biomarker levels returned to baseline, and while echocardiographic measures 1 year post closure were indicative of reverse cardiac remodeling, biomarker levels did not further decrease.

CONCLUSION

Percutaneous ASD closure in adults leads to a direct increase in most blood biomarkers, in particular hs-CRP and hs-TnT. After three months, biomarkers returned to baseline levels and remained stable up to one year.

Для цитирования: Geenen Laurie W, Uchoa de Assis Lucas, Baggen Vivan J M, Eindhoven Jannet A, Cuypers Judith A A E, Boersma Eric, Roos-Hesselink Jolien W, van den Bosch Annemien E. Evolution of blood biomarker levels following percutaneous atrial septal defect closure in adults.. International journal of cardiology. Heart & vasculature. 2020. DOI: 10.1016/j.ijcha.2020.100582.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.