MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0032-1312745

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2012

[Experiences with ultrasound-guided port implantations via the lateral subclavian vein: a retrospective analysis of 1532 patients].

Chang D-H, Boecker J, Hellmich M, Krug K B

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Evaluation of the success and complication rates in ultrasound-guided central venous port implantations through the lateral subclavian vein.

MATERIALS AND

METHODS

A total of 1537 subcutaneous central venous ports were implanted in 1532 patients. The catheter remained in place for a mean duration of 202 days (overall 309,464 catheter days). A retrospective analysis within the hospital and radiological information system (HIS/RIS) was performed to assess technical success and complication rates.

RESULTS

The implantations of the central venous ports were performed by 21 radiologists (19 residents). The technical success rate was 99.0 % (1517/1537) and the overall complication rate was 8.5 % (130/1537; 0.42 per 1000 catheter days). Procedural and acute complications (< 24 h) occurred in 22 of 1532 patients (1.4 %). Follow-up revealed 45 port explantations ahead of time due to complications in the early (< 30 d) or late (> 31 d) post-interventional period (2.9 %; 0.15 per 1000 catheter days). Catheter-associated vein thrombosis was the most common complication (n = 60, 3.9 %, 0.19 per 1000 catheter days).

CONCLUSION

Ultrasound-guided insertion of central venous port catheters through the lateral subclavian vein provides safe vascular access. Procedural complication rate is low with special regard to post-graduate training. The most common reasons for early port explantations were catheter-associated infections and vessel occlusions.

Для цитирования: Chang D-H, Boecker J, Hellmich M, Krug K B. [Experiences with ultrasound-guided port implantations via the lateral subclavian vein: a retrospective analysis of 1532 patients].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2012. DOI: 10.1055/s-0032-1312745.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.