MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/08927790261416031

Медицинская библиотека · Journal of endourology · 2026

Incidence of Acute Urinary Retention/Failure to Void after Transurethral Interventions for Benign Prostatic Enlargement: Results from a Systematic Review and Meta-Analysis of Comparative Randomized Studies by the FUTURE Collaborative of the Endourological Society.

Castellani Daniele, Akand Murat, Giulioni Carlo, Cormio Angelo, DiBianco John Michael, De Smita, Hajiha Mohammad, Quarrier Scott, Lee Hsiang Ying, Polascik Thomas James, Yuen Steffi Kar-Kei, Gauhar Vineet, Ghani Khurshid R, Maheshwari Pankaj N

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To perform a systematic review and meta-analysis to assess the incidence of acute urinary retention (AUR)/failure to void after transurethral surgeries for benign prostatic enlargement, comparing Ablation, Enucleation, and Resection (TURP) techniques.

MATERIALS AND

METHODS

A systematic literature search was performed on October 13, 2025 using Cochrane Central Register of Controlled Trials, PubMed, and Scopus. We only included randomized studies comparing monopolar TURP (M-TURP) or bipolar TURP (B-TURP) vs Ablation vs Enucleation procedures. Incidence of AUR/failure to void following the index surgery was evaluated using the Cochran-Mantel-Haenszel method and reported as risk ratio (RR), 95% confidence interval (CI), and p values. Statistical significance was set at p < 0.05.

EVIDENCE SYNTHESIS: A total of 61 studies were included, with 1497 patients in the Enucleation, 2512 patients in the Ablation, and 4007 patients in the TURP groups. The pooled incidence of AUR/failure to void was 3.7% (72/1944 patients) after M-TURP, 3.0% (47/1553 patients) after B-TURP, 9.0% (226/2512 patients) after Ablation, and 2.4% (36/1497 patients) after Enucleation. Meta-analysis showed no significant difference between Enucleation and TURP (RR 0.90, 95% CI 0.61-1.32, p = 0.59; I2 = 0%) in AUR/failure to void rate. Conversely, Ablation was associated with a significantly higher incidence of AUR/failure to void compared with TURP (RR 1.79, 95% CI 1.38-2.31, p < 0.001; I2 = 22%). Subgroup analyses revealed that this difference persisted for diode laser (RR 4.53, 95% CI 1.24-16.47), monopolar electrovaporization (RR 3.24, 95% CI 1.90-5.55), and Neodymium (Nd):YAG laser/RR 2.61, 95% CI 1.54-4.42) ablation techniques. No significant difference was found between M-TURP, B-TURP, and Enucleation, and between B-TURP and Ablation. Conversely, AUR/failure to void incidence favored M-TURP over Ablation (RR 1.88, 95% CI 1.40-2.52, p < 0.001).

CONCLUSIONS

Enucleation procedures demonstrate comparable safety to TURP regarding postoperative AUR/failure to void, whereas Ablation procedures are associated with a significantly higher incidence of postoperative retention events, particularly with energy modalities such as monopolar electrocautery, diode, and Nd:YAG lasers.

Для цитирования: Castellani Daniele, Akand Murat, Giulioni Carlo, Cormio Angelo, DiBianco John Michael, De Smita, Hajiha Mohammad, Quarrier Scott, Lee Hsiang Ying, Polascik Thomas James, Yuen Steffi Kar-Kei, Gauhar Vineet, Ghani Khurshid R, Maheshwari Pankaj N. Incidence of Acute Urinary Retention/Failure to Void after Transurethral Interventions for Benign Prostatic Enlargement: Results from a Systematic Review and Meta-Analysis of Comparative Randomized Studies by the FUTURE Collaborative of the Endourological Society.. Journal of endourology. 2026. DOI: 10.1177/08927790261416031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.