The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bosquet Laurent, Gouadec Kenan, Berryman Nicolas, Duclos Cyril, Gremeaux Vincent, Croisier Jean Louis
Аннотация
The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT) could be considered as a valid measure of anaerobic work capacity (AWC), such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT). Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s(-1), and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p < 0.05, Hedge's g = 4.27). Both measures were highly associated (r = 0.83), and the 95% limits of agreement (LoA) represented 24.5% of TWWAnT. TWFAT of knee flexors (2151 ± 540 J) was largely lower than TWWAnT (p < 0.05, g = 9.52). By contrast, both measures were not associated (r = 0.09), and the 95% LoA represented 31.1% of TWWAnT. Combining TWFAT of knee flexors and knee extensors into a single measure (6302 ± 818 J) did not changed neither improved these observations. We still found a large difference with TWWAnT (p < 0.05, g = 5.26), a moderate association (r = 0.65) and 95% LoA representing 25.5% of TWWAnT. We concluded that TWFAT of knee extensors could be considered as a valid measure of AWC, since both measure were highly associated. However, the mean difference between both measures and their 95% LoA were too large to warrant interchangeability. Key pointsTotal work performed during a high intensity isokinetic fatigue test can be considered as a valid measure of anaerobic work capacity (as determined by total work performance during a 30-s Wingate anaerobic test).The 95% limits of agreement are two large to allow a direct comparison between both measures. In other words, it is not possible to estimate the magnitude of performance improvement during a 30-s Wingate anaerobic test from that observed during a high intensity isokinetic fatigue test.In addition to provide sport scientists and coaches with measures of peak torque and ratios between agonists and antagonists muscles in a perspective of injury prevention, isokinetic dynamometry can also be used in the physiological assessment of athletes. However, some precautions should be taken in the interpretation of data.