MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-018-2051-5

Медицинская библиотека · BMC musculoskeletal disorders · 2018

Evaluation of three patient reported outcome measures following operative fixation of closed ankle fractures.

Garratt Andrew M, Naumann Markus G, Sigurdsen Ulf, Utvåg Stein Erik, Stavem Knut

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Several patient reported outcome measures (PROMs) are available for assessing the outcomes of ankle fracture but few have been compared for recommended measurement properties. This study compares the measurement properties of the Lower Extremity Function Scale (LEFS), Olerud Molander Ankle Score (OMAS) and Self-Reported Foot and Ankle Score (SEFAS) following ankle surgery.

METHODS

The retrospective cohort study included 959 patients aged 18 years and over who underwent surgical treatment (ORIF) for unstable and closed ankle fractures in SE Norway. The PROMs were included in a postal questionnaire sent to patients' homes in 2015, three years after surgery. Missing data, structural validity, internal consistency, test-retest reliability and validity were assessed.

RESULTS

Confirmatory factor analysis results showed model fit for the SEFAS and a bi-dimensional LEFS with scales of easy and difficult items. The OMAS performed less satisfactorily. Cronbach's alpha and test-retest correlations ranged from 0.82 to 0.96 and 0.91 to 0.93 respectively. The smallest detectable differences for group and individual comparisons were 14.1 to 20.6 and 0.93 to 1.55; SEFAS performed best. As hypothesised, instrument scores were highly correlated and with those for the EQ-5D and SF-36 physical functioning. Mean imputation where half or more items are completed increased usable scores by 1.4-15.7% without affecting measurement properties.

CONCLUSIONS

The three instruments largely performed satisfactorily in relation to important measurement properties but the LEFS had evidence for two dimensions relating to easier and more difficult aspects of function. Mean imputation where half or more items are completed increased the number of usable responses for all three instruments. The three instruments represent different approaches to measuring outcomes and their content should be considered carefully when choosing between them. The SEFAS is designed for a range of foot disorders including ankle fractures and has the best measurement properties in this population.

Для цитирования: Garratt Andrew M, Naumann Markus G, Sigurdsen Ulf, Utvåg Stein Erik, Stavem Knut. Evaluation of three patient reported outcome measures following operative fixation of closed ankle fractures.. BMC musculoskeletal disorders. 2018. DOI: 10.1186/s12891-018-2051-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.