Transient amniotic fluid leakage after fetoscopic laser photocoagulation for twin-twin transfusion syndrome.
Аннотация
AIM: Iatrogenic premature rupture of membrane (PROM) is one of the major complications related to fetoscopic laser photocoagulation (FLP) for twin-twin transfusion syndrome (TTTS). However, amniotic fluid leakage (AFL) sometimes spontaneously disappears. This study evaluated the incidence and clinical characteristics of transient AFL after FLP.
METHODS
We retrospectively reviewed pregnancies that underwent FLP for TTTS at a single center. Patients with apparent AFL within 2 weeks after FLP were divided into two groups: transient AFL, defined by the disappearance of fluid leakage within a week; and PROM, if AFL persisted continuously for more than a week or premature birth occurred, including miscarriage, within a week of the first symptom of AFL.
RESULTS
Among 201 monochorionic twin pregnancies that underwent FLP during the study period, nine patients (4.5%) were diagnosed with AFL within a week after FLP. Four patients (2.0%) were classified as transient AFL and five as PROM. Median gestational age at FLP was not significantly different between the groups; operative time in the PROM group was significantly longer (P = 0.01). The surgery to delivery interval and median gestational age at delivery were greater in the transient AFL group (87.8 vs 17.6 days, P = 0.01; 32.5 vs 23.6 weeks, P = 0.01, respectively).
CONCLUSIONS
The incidence of transient AFL after FLP was 2%. Perinatal outcomes of transient AFL might be better than that of PROM.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.