m+Medelevator.RU
← Поиск публикаций
Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2014

Oesophageal capsule endoscopy versus oesophago-gastroduodenoscopy for the diagnosis of recurrent varices: a prospective multicentre study.

Клиническое исследование II фазыКонтролируемое клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Laurain Anne, de Leusse Antoine, Gincul Rodica, Vanbiervliet Geoffroy, Bramli Slim, Heyries Laurent, Martane Gabriel, Amrani Naima, Serraj Ilham, Saurin Jean-Christophe, Borentain Patrick, Filoche Bernard, Duburque Clotilde, Gaudric Marianne, Sogni Philippe, Dumortier Jérôme

Аннотация

BACKGROUND: Oesophago-gastroduodenoscopy is the standard method for the diagnosis of recurrent oesophago-gastric varices after endoscopic treatment and eradication. The aim of this study was to evaluate the PillCam Eso capsule endoscopy in this setting.

METHODS: Prospective, multicentre study in which patients with history of oesophageal varices treated by band ligation underwent PillCam Eso capsule and oesophago-gastroduodenoscopy. Capsule recordings were blindly read by two endoscopists. Indication for a new prophylactic treatment and patient satisfaction were determined for both procedures.

RESULTS: 80 patients (80% males, mean age: 57±12 years) were included, after a median delay of 16 months from last endoscopic treatment. Recurrent oesophageal varices requiring a new prophylactic treatment were detected in 26 patients (32.5%). The mean oesophageal transit time of the capsule was 153 s (range 2-930 s). Capsule sensitivity, specificity, negative and positive predictive values for indication of new prophylactic treatments were 65%, 83%, 83%, and 65%, respectively. Capsule adequately classified 77.5% of the patients for prophylaxis indication. Inter-observer concordance for capsule readings was 88% for the prophylaxis indication.

CONCLUSION: This study demonstrates that accuracy of PillCam Eso capsule for the diagnosis of recurrent oesophageal varices after endoscopic eradication is suboptimal. PillCam Eso capsule might therefore be proposed in patients unable or unwilling to undergo oesophago-gastroduodenoscopy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты