Cuff leak volume as a clinical predictor for identifying post-extubation stridor.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Keeratichananont Warangkana, Limthong Teeranan, Keeratichananont Suriya
Аннотация
BACKGROUND: Post-extubation stridor occurs after translaryngeal intubation results to re-intubation in a number of patients.
OBJECTIVE: To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor
MATERIAL AND METHOD: Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. Clinical stridor was observed and identified after extubation.
RESULTS: Among 115 patients, the cuff leak volume of less than 114 ml was used to predict post-extubation stridor with the sensitivity of 89%, specificity of 90%, positive predictive value of 65%, and negative predictive value of 98%, respectively. Among the stridor group, 12 of 19 cases (63.2%) needed re-intubation.
CONCLUSION: The cuff leak volume of less than 114 ml can be used as a clinical predictor for identifying post-extubation stridor
OBJECTIVE: To determine the cut-off value of the cuff leak volume test among Thai patients as a predictor for post-extubation stridor
MATERIAL AND METHOD: Demographic data and cuff leak volume were collected from patients who had been intubated with planned extubation. Clinical stridor was observed and identified after extubation.
RESULTS: Among 115 patients, the cuff leak volume of less than 114 ml was used to predict post-extubation stridor with the sensitivity of 89%, specificity of 90%, positive predictive value of 65%, and negative predictive value of 98%, respectively. Among the stridor group, 12 of 19 cases (63.2%) needed re-intubation.
CONCLUSION: The cuff leak volume of less than 114 ml can be used as a clinical predictor for identifying post-extubation stridor