DOI 10.1016/j.fertnstert.2011.05.098
Hysteroscopic morcellator system can be used for removal of a uterine septum.
Аннотация
OBJECTIVE
To evaluate whether the hysteroscopic morcellator (HM) can be used as an alternative for uterine septum removal.
DESIGN
Case report.
SETTING
Outpatient clinic of a university-affiliated teaching hospital (Catharina Hospital, Eindhoven, the Netherlands).
PATIENT(S): A 34-year-old Asian woman with recurrent miscarriages and a large uterine septum and bicornuate uterus.
INTERVENTION(S): Septum removal using the HM.
MAIN OUTCOME MEASURE(S): Successful removal of a uterine septum.
RESULT(S): Considering obstetric complications, septum removal was carried out. Currently, septum transection using the resectoscope is the gold standard. Instead of transection we achieved nearly complete removal of a septum, using the HM.
CONCLUSION(S): The HM is a safe, effective, and easily manageable alternative for uterine septum removal compared with classic resectoscopy.