Intra-individual variation of the cuff-leak test as a predictor of post-extubation stridor.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gros Antoine, Holzapfel Laurent, Marqué Sophie, Perard Laurent, Demingeon Guy, Piralla Bonavie, Gaillard Sandrine, Tchenio Xavier
Аннотация
BACKGROUND: This was an evaluation of intra-individual variation of the cuff-leak test (ΔCLT) immediately post-intubation and pre-extubation, as a predictor of post-extubation stridor.
METHODS: Prospective, clinical investigation in the ICU of a non-university hospital. CLTs were performed immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak (ΔCLT = CL(T1) - CL(T0)).
RESULTS: We included 104 mechanically ventilated subjects in the study over a 12-month period. The incidence of post-extubation stridor was 6.7%. Stridor was more common in females of short stature. ΔCLT was considered as significant when CL(T1) - CL(T0) was negative. The sensitivity and the specificity of the test were 86% and 48%, respectively. When we tested the pre-extubation CLT alone with a threshold of 130 mL as a predictor of post-extubation stridor, the sensitivity and the specificity of the test were 86% and 76%, respectively.
CONCLUSIONS: The intra-individual variation of CLT immediately post-intubation and pre-extubation does not improve the accuracy of a standard pre-extubation CLT to predict post-extubation stridor. Moreover, the standard pre-extubation CLT did not appear in our study to be an ideal test to detect post-extubation stridor. Larger studies should be performed before generalizing these preliminary results.
METHODS: Prospective, clinical investigation in the ICU of a non-university hospital. CLTs were performed immediately after intubation (T0) and before extubation (T1) to evaluate the differences in cuff leak (ΔCLT = CL(T1) - CL(T0)).
RESULTS: We included 104 mechanically ventilated subjects in the study over a 12-month period. The incidence of post-extubation stridor was 6.7%. Stridor was more common in females of short stature. ΔCLT was considered as significant when CL(T1) - CL(T0) was negative. The sensitivity and the specificity of the test were 86% and 48%, respectively. When we tested the pre-extubation CLT alone with a threshold of 130 mL as a predictor of post-extubation stridor, the sensitivity and the specificity of the test were 86% and 76%, respectively.
CONCLUSIONS: The intra-individual variation of CLT immediately post-intubation and pre-extubation does not improve the accuracy of a standard pre-extubation CLT to predict post-extubation stridor. Moreover, the standard pre-extubation CLT did not appear in our study to be an ideal test to detect post-extubation stridor. Larger studies should be performed before generalizing these preliminary results.