MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5606/ehc.2017.52891

Медицинская библиотека · Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery · 2017

Is it possible to avoid intra-articular screw penetration with minimal use of fluoroscopy in the application of distal radius volar plate?

Aldemir Cengiz, Duygun Fatih

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aims to investigate whether or not it is possible to avoid intra-articular screw penetration in the application of distal radius volar plate with minimal use of fluoroscopy and thereby reduce to a minimum the risk of exposure of the surgical team to radiation.

PATIENTS AND

METHODS

Volar plate with distal screw application with minimal use of fluoroscopy was performed in a total of 50 patients (22 males, 28 females; mean age 43.52 years; range 18 to 76 years) with unstable distal radius fracture following reduction of fracture between June 2014 and May 2016. A specially designed volar anatomic plate was applied by creating a 3 mm gap proximal from the tip of the facet of the lunate fossa.

RESULTS

No intra-articular screw complication was observed during plate-screw applications that we performed by using fluoroscopy at a minimum level and paying attention to the surgical technique described with the plate designed by giving a specific angle to screw beds. During the operation, fluoroscopy was performed at a minimum level and no finding was observed which could suggest use of intra-articular screw. No findings of restriction in wrist movements, locking or friction were observed intra- or postoperatively.

CONCLUSION

With improvements in the design of the volar plate and the distal locking screw bed, it is possible to rule out the possibility of intra-articular screw complications and the need for surgical re-correction in the early-term, and to reduce to a minimum the risk of exposure of the surgical team to radiation.

Для цитирования: Aldemir Cengiz, Duygun Fatih. Is it possible to avoid intra-articular screw penetration with minimal use of fluoroscopy in the application of distal radius volar plate?. Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery. 2017. DOI: 10.5606/ehc.2017.52891.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.