Acta radiologica (Stockholm, Sweden : 1987) · 2014

Comparison of mammographic density estimation by Volpara software with radiologists' visual assessment: analysis of clinical-radiologic factors affecting discrepancy between them.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Han Na, Sohn Yu-Mee, Han Kyung Hwa

Аннотация

BACKGROUND: Volumetric breast density analysis is useful for quantitative mammographic assessment. However, there are few studies about clinical-radiologic factors contributing to discrepancies in the visual assessment by radiologists.

PURPOSE: To compare automated volumetric breast density measurement with BI-RADS breast density category by radiologists' visual assessments and to evaluate the clinical-radiologic factors affecting disagreement between two estimations.

MATERIAL AND METHODS: From February 2011 to September 2012, 860 patients (mean age, 54.7 ± 10.2 years) who had undergone digital mammography including fully automated volumetric breast density analysis, were enrolled. The agreement in breast density assessments between two radiologists, and between an experienced radiologist and the automated software were evaluated using a weighted kappa (k) value. Clinical-radiologic factors contributing to disagreement between the results obtained by a radiologist and the automated software were evaluated using univariate and multivariate analysis.

RESULTS: Breast density assessments obtained by two different radiologists were in good agreement (weighted k statistics 0.835%; 95% confidence interval [CI], 0.8098-0.8608); breast density assessments obtained by an experienced radiologist versus automated software were in moderate agreement (weighted k statistics 0.799%; 95% CI, 0.7708-0.8263). Univariate analysis identified a difference in bilateral breast density and patient age as two factors that significantly contributed to disagreement between the two approaches (P = 0.0002, P = 0.019). Multivariate analysis only identified a difference in bilateral breast density as a contributing factor.

CONCLUSION: The automated volumetric breast density measurement showed good agreement with radiologists' assessment. The difference in bilateral breast density affected the disagreement between results from visual assessment and automated software.