MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0335743

Медицинская библиотека · The Review of scientific instruments · 2026

Integrated frequency-modulated continuous-wave (FMCW) interferometer with in situ common-path referencing for plasma diagnostics using a commercial radar system-on-chip.

Yu Jinuo, Xie Jinlin, Guo RuoXuan, Yang Jinchen, Xu Yiduo, Zhuang Ge

СтатьяПеревод в очереди

Аннотация

Millimeter-wave interferometry is a standard diagnostic for line-integrated electron density, but conventional implementations typically rely on discrete high-frequency sources, mixers, and separately aligned reference paths. Here, we report an integrated frequency-modulated continuous-wave interferometer for plasma diagnostics using a commercial 60-64 GHz radar system-on-chip and, critically, an in situ common-path reference architecture that enables phase-stable operation with industrial hardware. The key design feature is the intentional use of aperture-clipping reflection from the diagnostic-window flange as a stationary reference echo, while the transmitted beam core traverses the plasma and is reflected by a mirror. Because the reference and measurement echoes are generated by the same chirp and share the same transceiver, launch optics, and diagnostic port, differential phase extraction suppresses common-mode oscillator drift, thermal drift, and mechanical vibration without a separate reference arm. A high-duty-cycle chirp configuration and chirp-by-chirp FFT phase retrieval provide a temporal resolution of 120 μs. Experiments on the Keda Linear Magnetized Plasma device show that the common-path-referenced scheme reduces the phase standard deviation from 0.34° to 0.17° and suppresses the dominant 22 Hz vibration component by more than 12 dB, yielding a minimum detectable line-integrated density of 2 × 1014 m-2. These results demonstrate a compact and scalable interferometer architecture for plasma diagnostics based on commercially integrated millimeter-wave hardware.

Для цитирования: Yu Jinuo, Xie Jinlin, Guo RuoXuan, Yang Jinchen, Xu Yiduo, Zhuang Ge. Integrated frequency-modulated continuous-wave (FMCW) interferometer with in situ common-path referencing for plasma diagnostics using a commercial radar system-on-chip.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0335743.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.