MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bone.2019.07.018

Медицинская библиотека · Bone · 2019

Timed up-and-go test is a useful predictor of fracture incidence.

Jeong Su-Min, Shin Dong Wook, Han Kyungdo, Jung Jin Hyung, Chun Sohyun, Jung Hee-Won, Son Ki Young

СтатьяПеревод в очереди

Аннотация

PURPOSE: The timed up-and-go (TUG) test is a validated screening tool to assess fall risk. This study evaluated the association between the TUG test and future fractures, which are a tangible clinical complication of falling.

METHODS

We included 1,070,320 participants who participated in the National Screening Program for Transitional Ages for Koreans aged 66 years old from 2009 to 2014. Among them, 355,753 women underwent dual-energy X-ray absorptiometry. TUG times were classified as <10 s or ≥10 s. The incidence of fractures, including vertebral, hip, and other sites, was determined using claims data from the National Health Information database.

RESULTS

During the mean follow-up period of 4.4 ± 1.8 years, participants with slow TUG times had a significantly increased risk of fractures compared with those who had normal TUG times: any fractures (adjusted hazard ratio [aHR] = 1.08, 95% confidence interval [CI] = 1.06-1.10), vertebral fracture (aHR = 1.14, 95% CI = 1.11-1.16), hip fracture (aHR = 1.21, 95% CI = 1.13-1.29), and other fractures (upper arm, forearm, and lower leg; aHR = 1.02, 95% CI = 1.00-1.05). Among women with bone mineral density (BMD) results, slow TUG performance was associated with an increased risk of fracture independent of BMD.

CONCLUSIONS

The TUG test, as an indicator of physical performance, can provide information about future fracture risk above that provided by BMD. Conducting the TUG test to assess fracture risk should be considered to improve fracture risk assessment and propose interventions to improve physical performance, thereby reducing fracture risk.

Для цитирования: Jeong Su-Min, Shin Dong Wook, Han Kyungdo, Jung Jin Hyung, Chun Sohyun, Jung Hee-Won, Son Ki Young. Timed up-and-go test is a useful predictor of fracture incidence.. Bone. 2019. DOI: 10.1016/j.bone.2019.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.