m+Medelevator.RU
← Поиск публикаций
Analytical chemistry · 2020

Metal Ion-Mediated Potential-Resolved Ratiometric Electrochemiluminescence Bioassay for Efficient Determination of miR-133a in Early Diagnosis of Acute Myocardial Infarction.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Jue, Haghighatbin Mohammad A, Shen Wen, Mi Lan, Cui Hua

Аннотация

Potential-resolved electrochemiluminescence (PRECL)-based strategies utilizing novel nanoluminophores have become a research hotspot in analytical sciences in virtue of the superior versatility, specificity, and sensitivity they offer to bioassays. In this work, novel PRECL nanoluminophore graphitic carbon nitrides (g-C3N4) functionalized by N-(aminobutyl)-N-(ethylisoluminol) (ABEI) (g-C3N4/ABEI) were developed, exhibiting two potential-resolved ECL emissions in the presence of H2O2/K2S2O8 as coreactants with the peak potentials at +1.2 and -1.6 V, respectively. It was found that Hg2+ could simultaneously decrease the ABEI electrochemiluminescence (ECL) intensity while increasing the intensity of g-C3N4 on the contrary. Using Hg2+ as the ECL signal moderator based on specific interactions between Hg2+ and thymine-thymine pairs, conjoined with the synthesized g-C3N4/ABEI/Hg2+ nanohybrids with outstanding PRECL properties as the sensing interface, a label-free and all-in-one ratiometric ECL bioassay combined with a rolling circle amplification (RCA) strategy was designed for the detection of miR-133a as a biomarker in early diagnosis of acute myocardial infarction (AMI). The proposed bioassay provided a quantitative readout proportional to the target miR-133a concentrations in the range from 0.1 fM to 1.0 pM with a detection limit of 48.0 aM. Owing to its inherent merits for an effective amplification of the ECL signals ratio and a simple one-step assembly procedure, the proposed bioassay demonstrated excellent analytical performance with remarkable sensitivity, specificity, and low measurement deviations, manifesting its potential application in early AMI diagnosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты