INTRODUCTION

Transseptal puncture (TSP) is challenging in patients with prior percutaneous atrial septal defect (ASD) occluder. We aimed to perform a systematic review and meta-analysis of the safety and efficacy of catheter ablation for atrial fibrillation (AF) in patients with percutaneous ASD occluder.

METHODS

We searched PubMed, Medline, Embase, Ovid, and Cochrane for studies reporting results of AF ablation (freedom from AF, fluoroscopy/procedure time, and complications) in patients with percutaneous ASD occluders.

RESULTS

Three studies with a total of 64 patients met inclusion criteria. The success rate of TSP was 100%. All patients (but one) underwent TSP under fluoroscopic and intracardiac echocardiography guidance. Freedom from AF was achieved in 77.7% (95% confidence interval [CI]: 65.7-86.3) patients. In the subgroup analysis, comparing septal versus device puncture, no significant difference in recurrence of AF was observed (23.07% vs. 16.66%; risk ratio: 1.18; 95% CI: 0.35-4.00; p = .79, respectively). The total fluoroscopy time was not significantly different in patients with TSP via native septum or device (43.50 vs. 70.67 min; p = .44), total procedural time was significantly longer with TSP via the closure device (237.3 vs. 180 min; p = .004) compared with the native septum. There were no device dislodgement or residual interatrial shunt during the follow-up period.

CONCLUSION

Catheter ablation for AF in patients with prior percutaneous ASD closure device is feasible and safe with favorable long-term outcomes.

Для цитирования: Garg Jalaj, Shah Kuldeep, Turagam Mohit K, Janagam Pragna, Natale Andrea, Lakkireddy Dhanunjaya. Safety and efficacy of catheter ablation for atrial fibrillation in patients with percutaneous atrial septal closure device: Electrophysiology Collaborative Consortium for Meta-analysis-ELECTRAM Investigators.. Journal of cardiovascular electrophysiology. 2020. DOI: 10.1111/jce.14616.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.