MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2013.10.024

Медицинская библиотека · Ophthalmology · 2013

The ability of healthy volunteers to simulate a neurologic field defect on automated perimetry.

Ghate Deepta, Bodnarchuk Brian, Sanders Sheila, Deokule Sunil, Kedar Sachin

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine if volunteers can simulate and reproduce 3 types of neurologic field defects: hemianopia, quadrantanopia, and central scotoma.

DESIGN

Cross-sectional study.

PARTICIPANTS

Thirty healthy volunteers new to perimetry (including automated perimetry).

METHODS

After informed consent, volunteers were randomized to 1 of the 3 visual field defects listed above. All visual field testing was performed on the right eye using the Humphrey Field Analyzer (HFA; Carl Zeiss Meditec, Dublin, CA) SITA Fast 24-2 protocol. Each volunteer was provided with standard new patient instructions and was shown a diagram of the defect to be simulated. Two sets of visual fields were performed on the right eye with 10 minutes between tests. Three experts used the Ocular Hypertension Treatment Study reading center criteria and determined if the simulation was successful.

MAIN OUTCOME MEASURES: Proportion of volunteers able to simulate the assigned visual field.

RESULTS

All 10 volunteers (100%) successfully simulated a hemianopia on the first and second fields. All 10 volunteers (100%) simulated a quadrantanopia on the first field and 9 (90%) did so on the second field. Eight volunteers (80%) successfully simulated a central scotoma in the first field and all 10 (100%) did so on in the second field. Reliability criteria were excellent. Forty-seven fields (78%) had 0 fixation losses, 48 (80%) had 0 false-positive results, and 44 (73%) had 0 false-negative results.

CONCLUSIONS

It is easy to simulate reproducible and reliable neurologic field defects on automated perimetry using HFA.

Для цитирования: Ghate Deepta, Bodnarchuk Brian, Sanders Sheila, Deokule Sunil, Kedar Sachin. The ability of healthy volunteers to simulate a neurologic field defect on automated perimetry.. Ophthalmology. 2013. DOI: 10.1016/j.ophtha.2013.10.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.