m+Medelevator.RU
← Поиск публикаций
Journal of sleep research · 2019

Quantitative assessment of the quality of home sleep studies: A computer-assisted approach.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Maestri Roberto, Robbi Elena, Lovagnini Marta, Taurino Anna Eugenia, Fanfulla Francesco, Pinna Gian Domenico

Аннотация

Home monitoring is the most practical means of collecting sleep data in large-scale research investigations. Because the portion of recording time with poor-quality data is higher than in attended polysomnography, a quantitative assessment of the quality of each signal should be recommended. Currently, only qualitative or semi-quantitative assessments are carried out, likely because of the lack of computer-based applications to carry out this task efficiently. This paper presents an innovative computer-assisted procedure designed to perform a quantitative quality assessment of standard respiratory signals recorded by Type 2 and Type 3 portable sleep monitors. The proposed system allows to assess the quality (good versus bad) of consecutive 1-min segments of thoraco-abdominal movements, oronasal, nasal airflow and oxygen saturation through an automatic classifier. The performance of the classifier was evaluated in a sample of 30 unattended polysomnography recordings, comparing the computer output with the consensus of two expert scorers. The difference (computer versus scorers) in the percentage of good-quality segments was on average very small, ranging from -3.1% (abdominal movements) to 0.8% (nasal flow), with an average total classification accuracy from 90.2 (oronasal flow) to 94.9 (nasal flow), a Sensitivity from 0.93 (oronasal flow) to 0.98 (nasal flow), and a Specificity from 0.74 (nasal flow) to 0.86 (abdominal movements). In practical applications, the scorer can run a check-and-edit procedure, further improving the classification accuracy. Considering a sample of 270 unattended polysomnography recordings (recording time: 545 ± 44 min), the average time taken for the check-and-edit procedure of each recording was 6.9 ± 2.1 min for all respiratory signals.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты