m+Medelevator.RU
← Поиск публикаций
Colloids and surfaces. B, Biointerfaces · 2023

Nanoengineered phosphorus doped graphitic carbon nitride based ultrasensitive biosensing platform for Swine flu detection.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nirbhaya Vishakha, Chandra Ramesh, Kumar Suveen

Аннотация

In the present study, we developed an amino-polyindole modified phosphorus doped graphitic carbon nitride nanomaterial (APIN/P-g-C3N4) based immunosensing biochip for Serum amyloid A (SAA) biomarker towards early diagnosis of Swine flu. The P-g-C3N4 was synthesis via polycondensation and functionalized with APIN. Further, the biochip was fabricated by modifying the working area of SPE with APIN/P-g-C3N4 using drop cast method, APIN introduced the larger loading of -NH2 group moieties onto P-g-C3N4 matrix and benefitted to reinforced the biomolecules via covalent linkages. The monoclonal anti-SAA was conjugated onto APIN/P-g-C3N4/SPE using EDC-NHS chemistry and BSA was added for non-specific site blocking. The structural, chemical, composition and morphological characteristics of the synthesized, functionalized nanomaterial and fabricated biochips were investigated by XRD, XPS, FT-IR spectroscopy, SEM, FE-SEM and TEM techniques. Further, the electrochemical characterization and response studies of fabricated biochip were analyzed using the CV and DPV techniques. Based on the analytical performance of the proposed immunosensing biochip i.e. BSA/anti-SAA/APIN/P-g-C3N4/SPE, it is capable to detect SAA protein with ultra sensitivity of 79.5 μA log (mL ng-1) cm-2, ultralow limit of detection of 5 ng mL-1 and wider linear detection range of 5 ng mL-1-500 μg mL-1 with quick response time of 10 min. Moreover, the fabricated immunosensing biochips was used to analyse SAA protein in spiked serum samples and the achieved results demonstrated the good agreement with the electrochemical response observed in standard SAA protein samples in analytical solution. The proposed biochip can provide insights for developing a wide range of clinical screening tools for detecting various contagious diseases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты