m+Medelevator.RU
← Поиск публикаций
Infection · 2026

Comparative evaluation of multimodal point-of-care tests to differentiate gram-negative from gram-positive infections in critically ill adults: a diagnostic accuracy study.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Huang Weijia, Yang Ting, Ma Sinan, Wang Jiatian, Gong Huangxin, Wang Haitao, Sun Jingying, Wang Na, Zhang Li, Wang Yan

Аннотация

PURPOSE: Patients with suspected sepsis often receive broad-spectrum antibiotics before culture results are available. A rapid point-of-care test (POCT) that indicates Gram-negative (GN) versus Gram-positive (GP) infection could help tailor empiric therapy. We systematically compared available POCT for GN/GP differentiation and, for biomarkers, examined clinically usable thresholds.

METHODS: PubMed, Embase, Web of Science and the Cochrane Library (January 2005 to August 2025) were searched for studies in adults with sepsis that evaluated rapid tests to distinguish GN from GP infection. We pooled host-response biomarkers, pathogen-directed assays, omics-based tests, and clinical-parameter approaches using a bivariate random-effects model to obtain pooled sensitivity, specificity, area under the curve (AUC) and Youden's index. For biomarkers reported at multiple cut-offs, clinically relevant strata were prespecified and compared.

RESULTS: Of 86 included studies, 72 were eligible for quantitative synthesis. Pathogen-directed rapid assays (PCR, MALDI-TOF MS) showed the highest and most consistent accuracy (pooled sensitivity and specificity > 0.90; AUC 0.97-0.99; Youden 0.85-0.92). Among the biomarker studies, procalcitonin (PCT) showed clear threshold dependence: the 3-5 ng/mL stratum provided the most balanced discrimination (sensitivity 0.84; specificity 0.83; AUC 0.90; Youden 0.67), whereas higher cut-offs did not yield further gains. Omics-based approaches showed variable accuracy, and clinical-parameter approaches alone achieved sensitivity and specificity < 0.70.

CONCLUSION: In adults with sepsis, pathogen-directed rapid assays are the most reliable POCT for early GN/GP differentiation. When biomarker testing is available, a PCT range of 3-5 ng/mL is a pragmatic working threshold that can support earlier tailoring of empiric antimicrobial therapy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты