MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jss.2017.06.080

Медицинская библиотека · The Journal of surgical research · 2018

Echocardiography allows for analysis of pulmonary arterial flow in mice with congenital diaphragmatic hernia.

Shah Mansi, Phillips Michael R, Quintana Megan, Stupp Gary, McLean Sean E

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Congenital diaphragmatic hernia (CDH) is a structural birth defect associated with pulmonary hypoplasia and pulmonary arterial hypertension (PAH). We hypothesize that echocardiography provides a method to assess real-time right ventricle (RV) function, remodeling, and pulmonary artery (PA) flow.

MATERIALS AND

METHODS

Slit3 wild-type (WT) (n = 6) and knockout (KO) (n = 5) mice were analyzed at 2-3 months of age. Mice were anesthetized using isoflurane. Echocardiography was performed to analyze left and right ventricular wall thickness, internal diameter (ID), and function. Color Doppler was used to analyze flow in the PA and across the tricuspid valve.

RESULTS

There was significant RV dilation in the KO mice versus WT, with an average RVID of 1.99 mm versus 1.26 mm, respectively (P = 0.007). Flow in the PA of KO mice was altered compared to WT, with elevated PA velocity time indices, 30.68 mm versus 22.13 mm (P = 0.012), elevated PA peak velocities, 952.61 mm/s versus 628.73 mm/s (P = 0.003), and decreased pulmonary acceleration times, 8.94 ms versus 16.18 ms (P = 0.002), respectively. Pulmonary vascular resistance, calculated by measuring tricuspid regurgitation peak velocity and right ventricular outflow tract velocity time index, was increased in KO versus WT mice, 17.61 mm2/s versus 8.91 mm2/s (P = 0.003), respectively.

CONCLUSIONS

Slit3 KO mice with CDH show evidence of PAH and resultant RV dilation. Using direct cardiac puncture, elevated RV systolic pressures have been demonstrated in KO mice as evidence of PAH. Echocardiography allows direct analysis of the PA and real-time RV function without sacrifice of the mouse. This mode of evaluation allows longitudinal study in mice with PAH and CDH.

Для цитирования: Shah Mansi, Phillips Michael R, Quintana Megan, Stupp Gary, McLean Sean E. Echocardiography allows for analysis of pulmonary arterial flow in mice with congenital diaphragmatic hernia.. The Journal of surgical research. 2018. DOI: 10.1016/j.jss.2017.06.080.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.