MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/tp.0000000000002265

Медицинская библиотека · Transplantation · 2018

Detection of Complement-binding Donor-specific Antibodies, Not IgG-antibody Strength Nor C4d Status, at Antibody-mediated Rejection Diagnosis Is an Independent Predictor of Kidney Graft Failure.

Malheiro Jorge, Santos Sofia, Tafulo Sandra, Dias Leonídio, Martins La Salete, Fonseca Isabel, Almeida Manuela, Pedroso Sofia, Beirão Idalina, Castro-Henriques António, Cabrita António

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Antibody-mediated rejection (AMR) remains associated with reduced kidney graft survival and no clear prognostic marker is available.

METHODS

We investigated whether donor-specific antibodies (DSA) ability to bind C1q in comparison with AMR C4d status, both indirect signs of complement activation, improve risk stratification at time of AMR. Hence, among 467 patients in whom 1 or more graft biopsies were performed between 2008 and 2015, we included 56 with AMR according to Banff '15 criteria. Using concurrent sera, we prospectively identified DSA by single-antigen beads (IgG and C1q) assays.

RESULTS

Antibody-mediated rejection C4d (+) (n = 28) was associated with preformed DSA (P = 0.007), whereas DSA C1q (+) (n = 25) cases had stronger IgG-DSA (P < 0.001). At AMR, graft function was similar between DSA C1q groups, but in the first year after, it improved in DSA C1q (-), whereas a steady decline was observed in DSA C1q (+) cases, remaining significantly lower from 1 year until 4 years after AMR. DSA C1q (+) was significantly associated with reduced graft survival (P = 0.021), whereas AMR C4d (+) was not (P = 0.550). Importantly, a similar negative impact of DSA C1q (+) on graft survival was observed within AMR C4d (+) (P = 0.040) and (-) (P = 0.036), cases. In multivariable analysis, DSA C1q (+) (hazard ratio, 3.939, P = 0.005) and de novo DSA (hazard ratio, 4.409, P = 0.033) were independent predictors of graft failure, but stronger IgG-DSA was not. Similar results were obtained considering C1q-DSA and IgG-DSA strength as continuous variables.

CONCLUSIONS

C1q-DSA assessment at AMR can be a valuable tool in detecting patients with higher risk of graft failure.

Для цитирования: Malheiro Jorge, Santos Sofia, Tafulo Sandra, Dias Leonídio, Martins La Salete, Fonseca Isabel, Almeida Manuela, Pedroso Sofia, Beirão Idalina, Castro-Henriques António, Cabrita António. Detection of Complement-binding Donor-specific Antibodies, Not IgG-antibody Strength Nor C4d Status, at Antibody-mediated Rejection Diagnosis Is an Independent Predictor of Kidney Graft Failure.. Transplantation. 2018. DOI: 10.1097/tp.0000000000002265.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.