PURPOSE: To evaluate novice and senior vitreoretinal surgeons after various exposures. Multiple comparisons ranked the importance of these exposures for surgical dexterity based on experience.
METHODS
This prospective cohort study included 15 novice and 11 senior vitreoretinal surgeons (<2 and >10 years' practice, respectively). Eyesi-simulator tasks were performed after each exposure. Day 1, placebo, 2.5 mg/kg caffeine, and 5.0 mg/kg caffeine; day 2, placebo, 0.2 mg/kg propranolol, and 0.6 mg/kg propranolol; day 3, baseline simulation, breathalyzer readings of 0.06% to 0.10% and 0.11% to 0.15% blood alcohol concentrations; day 4, baseline simulation, push-up sets with 50% and 85% repetitions maximum; and day 5, 3-hour sleep deprivation. Eyesi-generated score (0-700, worst-best), out-of-tolerance tremor (0-100, best-worst), task completion time (minutes), and intraocular pathway (in millimeters) were measured.
RESULTS
Novice surgeons performed worse after caffeine (-29.53, 95% confidence interval [CI]: -57.80 to -1.27, P = 0.041) and alcohol (-51.33, 95% CI: -80.49 to -22.16, P = 0.001) consumption. Alcohol caused longer intraocular instrument movement pathways (212.84 mm, 95% CI: 34.03-391.65 mm, P = 0.02) and greater tremor (7.72, 95% CI: 0.74-14.70, P = 0.003) among novices. Sleep deprivation negatively affected novice performance time (2.57 minutes, 95% CI: 1.09-4.05 minutes, P = 0.001) and tremor (8.62, 95% CI: 0.80-16.45, P = 0.03); however, their speed increased after propranolol (-1.43 minutes, 95% CI: -2.71 to -0.15 minutes, P = 0.029). Senior surgeons' scores deteriorated only following alcohol consumption (-47.36, 95% CI: -80.37 to -14.36, P = 0.005).
CONCLUSION
Alcohol compromised all participants despite their expertise level. Experience negated the effects of caffeine, propranolol, exercise, and sleep deprivation on surgical skills.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.