MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-020-07521-1

Медицинская библиотека · European radiology · 2020

Magnetic resonance T1w/T2w ratio in the middle cerebellar peduncle might be a sensitive biomarker for multiple system atrophy.

Sugiyama Atsuhiko, Yokota Hajime, Hirano Shigeki, Cooper Graham, Mukai Hiroki, Koide Kyosuke, Wang Jiaqi, Ito Shoichi, Finke Carsten, Brandt Alexander U, Paul Friedemann, Kuwabara Satoshi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We aimed to investigate the use of a myelin-sensitive MRI contrast, the standardized T1-weighted/T2-weighted (sT1w/T2w) ratio, for detecting early changes in the middle cerebellar peduncle (MCP) in cerebellar subtype multiple system atrophy (MSA-C) patients.

METHODS

We included 28 MSA-C patients, including a subset of 17 MSA-C patients within 2 years of disease onset (early MSA-C), and 28 matched healthy controls. T1w and T2w scans were acquired using a 3-T MR system. The sT1w/T2w ratio in MCP was analyzed using SPM12 by utilizing a region-of-interest approach in normalized space. The diagnostic performance of the MCP sT1w/T2w ratio in discriminating MSA-C and the subgroup of early MSA-C from the matched controls was assessed. Correlation analyses were performed to evaluate the relationship between the MCP sT1w/T2w ratio and other clinical parameters including the International Cooperative Ataxia Scale (ICARS) score for quantifying cerebellar ataxia.

RESULTS

Compared to controls, the sT1w/T2w ratio in the MCP was markedly lower in all (p < 0.001) MSA-C patients and 17 early (p < 0.001) MSA-C patients. The MCP sT1w/T2w ratio had high sensitivity (96%) and specificity (100%) to distinguish MSA-C from controls (area under the curve = 0.99), even for the early MSA-C group (area under the curve = 0.99; sensitivity = 94%, specificity = 100%). The MCP sT1w/T2w ratio correlated with the ICARS score in early MSA-C.

CONCLUSIONS

The sT1w/T2w ratio can detect MSA-C-related changes in the MCP, even in the early stages of the disorder, and could be a sensitive biomarker for MSA-C.

KEY POINTS: • The sT1w/T2w ratio can detect MSA-C-related changes in the middle cerebellar peduncle, even in the early stages of the disorder. • The middle cerebellar peduncle sT1w/T2w ratio correlated with a cerebellar ataxia score in early MSA-C patients.

Для цитирования: Sugiyama Atsuhiko, Yokota Hajime, Hirano Shigeki, Cooper Graham, Mukai Hiroki, Koide Kyosuke, Wang Jiaqi, Ito Shoichi, Finke Carsten, Brandt Alexander U, Paul Friedemann, Kuwabara Satoshi. Magnetic resonance T1w/T2w ratio in the middle cerebellar peduncle might be a sensitive biomarker for multiple system atrophy.. European radiology. 2020. DOI: 10.1007/s00330-020-07521-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.