MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8159.2011.03303.x

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2012

Subclavian venoplasty may reduce implant times and implant failures in the era of increasing device upgrades.

Ji Sang Yong, Gundewar Susheel, Palma Eugen C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The incidence of subclavian venous occlusions (SCVOs) may be an increasing problem in the era of device upgrades, especially to cardiac resynchronization therapy. Venoplasty (VP) performed by the electrophysiologist as a way of managing SCVOs may be advantageous.

METHODS

We reviewed the implantable cardioverter defibrillator (ICD) implants of the past 5 years at Montefiore Medical Center and searched for SCVOs that required intervention and compared cases where VP was performed with cases where it was not.

RESULTS

Of 1,853 ICD implants, 41 SCVOs (2.2%) requiring intervention were identified. Its incidence increased seven-fold from 0.7% in 2005 to 5.2% in 2009. Twenty-seven of the 41 SCVOs were found during a device upgrade. Of these 41 SCVOs, 18 underwent VP and 23 did not. In the VP group, there was a trend towards a shorter total procedure time, 2:31 hours versus 3:28 hours (P=0.37), and the total fluoroscopy time was 30 minutes versus 27 minutes (P=0.55). VP was successful in all 18 patients. Among the non-VP group (n=23), five (21.5%) had a failed implantation because of the inability to gain venous access and 10 (42.7%) had to be implanted on the contralateral side.

CONCLUSION

The incidence of SCVOs requiring intervention is increasing in the era of device upgrades. VP performed by an electrophysiologist appears to be a safe and efficient approach to manage these SCVOs. VP seems to reduce the implant time and the need to implant on the other side as well as implant failure due to the inability to gain venous access.

Для цитирования: Ji Sang Yong, Gundewar Susheel, Palma Eugen C. Subclavian venoplasty may reduce implant times and implant failures in the era of increasing device upgrades.. Pacing and clinical electrophysiology : PACE. 2012. DOI: 10.1111/j.1540-8159.2011.03303.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.