m+Medelevator.RU
← Поиск публикаций
Journal of personalized medicine · 2026

Clinical Value of Fluorescent Lymphography with Indocyanine Green During Robotic Surgery for Gastric Cancer in Guided Lymph Node Dissection: A Systematic Review and Meta-Analysis.

СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peristeri Dimitra V, Raptis Dimitrios N, Mantzoros Ioannis, Schizas Dimitrios, Asimakopoulos Alexandros-Georgios I, Papadopoulou Eirini, Lianos Georgios D, Papaziogas Thomas, Papaziogas Vasileios

Аннотация

Introduction: Robotic gastrectomy is increasingly used in the surgical management of gastric cancer. Indocyanine green (ICG) near-infrared fluorescence imaging has emerged as a technique that enables real-time visualization of lymphatic drainage pathways, potentially facilitating more precise and individualized lymph node dissection. However, the clinical value of ICG-guided fluorescent lymphography during robotic gastrectomy remains incompletely established. Methods: A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. PubMed, Embase, Scopus, and the Cochrane Library were searched from database inception to 31 January 2026 for comparative studies evaluating ICG-guided fluorescent lymphography versus standard robotic gastrectomy for gastric cancer. Statistical analyses were performed using R (version 4.4.2) and the meta package. Results: Six studies, including 406 patients, met the inclusion criteria. Use of ICG was associated with a higher number of retrieved lymph nodes (mean difference [MD] 8.48; 95% CI 4.61-12.36; p = 0.001; I2 = 55.5%). Operative time was modestly shorter in the ICG group (MD -10.84 min; 95% CI -21.08 to -0.61; p = 0.038). There were no significant differences in intraoperative blood loss (MD -4.02 mL; p = 0.289), length of hospital stay (MD -0.82 days; p = 0.131), or postoperative complications (odds ratio 0.83; 95% CI 0.46-1.49; p = 0.534). Conclusions: ICG-guided fluorescence imaging during robotic gastrectomy is associated with increased lymph node retrieval and a small reduction in operative time without evidence of increased perioperative morbidity. Larger prospective studies are required to confirm these findings and to evaluate long-term oncologic outcomes.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты