MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0102-86502013000300011

Медицинская библиотека · Acta cirurgica brasileira · 2013

Correlation between radiographic signs of third molar proximity with inferior alveolar nerve and postoperative occurrence of neurosensory disorders: a prospective, double-blind study.

Costa Fábio Wildson Gurgel, Fontenele Erick Helton Lima, Bezerra Tácio Pinheiro, Ribeiro Thyciana Rodrigues, Carneiro Bárbara Gressy Duarte Souza, Soares Eduardo Costa Studart

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the interference of radiographic factors in the appearance of sensory deficit related to inferior alveolar nerve (IAN) after third molars (3Ms) removal.

METHODS

A prospective, double-blind, observational, unicentric study was performed with 126 patients submitted to a surgical procedure of lower 3Ms removal in the period from March to October/2011. Collected data included gender, age, eruption stage of 3Ms, position/angle of 3Ms (Pell-Gregory and Winter classifications, respectively), presence/absence of radiographic signs of 3Ms proximity with the inferior alveolar canal and surgical technique. Occurrence evaluation of the IAN injury was performed on the seventh postoperative day through pin-prick, two-point discrimination and brush directional stroke tests.

RESULTS

Predominant radiographic signs were: narrowing of the inferior alveolar canal (68.25%), darkening of root (46.82%) and diversion of the canal (31%). None of the patients presented sensory loss. Sixty-one (48.41%) of the cases had at least one or two radiographic signs of proximity with NAI. Forty-seven (37.3%) had 3 or more signs, and 18 (14.29%) did not have any radiographic signs of proximity to mandibular canal.

CONCLUSION

There was not a positive correlation between presence of radiographic signs of 3Ms with IAN proximity and postoperative neurosensory disorders occurrence.

Для цитирования: Costa Fábio Wildson Gurgel, Fontenele Erick Helton Lima, Bezerra Tácio Pinheiro, Ribeiro Thyciana Rodrigues, Carneiro Bárbara Gressy Duarte Souza, Soares Eduardo Costa Studart. Correlation between radiographic signs of third molar proximity with inferior alveolar nerve and postoperative occurrence of neurosensory disorders: a prospective, double-blind study.. Acta cirurgica brasileira. 2013. DOI: 10.1590/s0102-86502013000300011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.