m+Medelevator.RU
← Поиск публикаций
Environmental research · 2022

Exposure to air pollution and risk of incident dementia in the UK Biobank.

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Parra Kimberly L, Alexander Gene E, Raichlen David A, Klimentidis Yann C, Furlong Melissa A

Аннотация

BACKGROUND: Air pollution may cause inflammatory and oxidative stress damage to the brain, leading to neurodegenerative disease. The association between air pollution and dementia, and modification by apolipoprotein E genotype 4 (APOE-ε4) has yet to be fully investigated.

OBJECTIVES: To examine associations of air pollution with three types of incident dementias (Alzheimer's disease (AD), frontotemporal dementia (FTD), and vascular dementia (VAD)), and their potential modification by APOE-ε4 genotype.

METHODS: The UK Biobank enrolled >500,000 participants (2006-2010) with ongoing follow-up. We used annual averages of air pollution (PM2.5, PM10, PM2.5-10, PM2.5absorbance, NO2, NOX) for 2010 scaled to interquartile ranges (IQR). We included individuals aged ≥60 years, with no dementia diagnosis prior to January 1, 2010. Time to incident dementia and follow-up time were reported from baseline (January 01, 2010) to last censor event (death, last hospitalization, or loss to follow-up). Cox proportional hazard ratios (HR) and 95% confidence intervals (95% CI) were calculated to estimate the association of air pollutants and incident dementia, and modification of these associations by APOE-ε4.

RESULTS: Our sample included 187,194 individuals (including N = 680 AD, N = 377 VAD, N = 63 FTD) with a mean follow-up of 7.04 years. We observed consistent associations of PM2.5 with greater risk of all-cause dementia (HR = 1.17, 95% CI: 1.10, 1.24) and AD (HR = 1.17, 95% CI: 1.06, 1.29). NO2 was also associated with greater risk of any incident dementia (HR = 1.18, 95% CI: 1.10, 1.25), AD (HR = 1.15, 95% CI: 1.04, 1.28) and VAD (HR = 1.18, 95% CI: 1.03, 1.35). APOE-ε4 did not modify the association between any air pollutants and dementia.

DISCUSSION: PM2.5 and NO2 levels were associated with several types of dementia, and these associations were not modified by APOE-ε4. Findings from the UK Biobank support and extend to other epidemiological evidence for the potential association of air pollutants with detrimental brain health during aging.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты