MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/nau.20182

Медицинская библиотека · Neurourology and urodynamics · 2005

A urodynamics protocol to optimally assess men with post-prostatectomy incontinence.

Huckabay Chad, Twiss Christian, Berger Aaron, Nitti Victor W

СтатьяПеревод в очереди

Аннотация

AIMS: To propose a urodynamic protocol to comprehensively assess all parameters of post prostatectomy incontinence (PPI).

METHODS

Sixty men with a history of PPI after radical prostatectomy prospectively underwent a standardized video urodynamics protocol. A 7F urethral catheter was used for standard cystometry, abdominal leak point pressure (ALPP), and pressure flow measurements. The International Continence Society nomogram classified obstruction and further classification of obstruction was based on fluoro voiding cystourethrography and non-invasive flow rates (free Qmax).

RESULTS

Twenty-four (40%) men had detrusor overactivity with 8 (13%) also having detrusor overactivity incontinence. Only one patient had impaired compliance. All men had urodynamic stress incontinence, but 21 (35%) men demonstrated it only after removal of the urethral catheter. For men leaking with and without the urethral catheter, the respective ALPP was significantly different, 86.3 and 67 cmH2O, respectively (P = 0.002). The men who leaked only in the absence of the urethral catheter had significantly higher ALPP measurements, P < 0.001. After reclassification using the fluoroscopic images of the bladder outlet and free Qmax, only 13.3% patients were obstructed.

CONCLUSIONS

The proposed urodynamic protocol allows for an optimal assessment of bladder and sphincter dysfunction and outlet obstruction in men with PPI.

Для цитирования: Huckabay Chad, Twiss Christian, Berger Aaron, Nitti Victor W. A urodynamics protocol to optimally assess men with post-prostatectomy incontinence.. Neurourology and urodynamics. 2005. DOI: 10.1002/nau.20182.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.