MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xjon.2020.02.002

Медицинская библиотека · JTCVS open · 2020

Evaluation of personalized right ventricle to pulmonary artery conduits using in silico design and computational analysis of flow.

Ebrahimi Pegah, Youssef David, Salve Gananjay, Ayer Julian, Dehghani Fariba, Fletcher David F, Winlaw David S

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Right ventricle to pulmonary artery (RV-PA) conduits are required for the surgical management of pulmonary atresia with ventricular septal defect and truncus arteriosus. Bioengineered RV-PA connections may address some of the shortcomings of homografts and xenografts, such as lack of growth potential and structural deterioration and may be manufactured to accommodate patient-specific anatomy. The aim of this study was to develop a methodology for in silico patient-specific design and analysis of RV-PA conduits.

METHODS

Cross-sectional imaging was obtained from patients with truncus arteriosus (n = 5) and pulmonary atresia with ventricular septal defect (n = 5) who underwent complete repair with a RV-PA conduit. Three-dimensional models of the heart were constructed by segmentation of the right ventricle, existing conduit, branch pulmonary arteries, and surrounding structures. A customized conduit design for each patient was proposed. Computational fluid dynamics analysis was performed and outputs, including wall shear stress and energy loss, were used to compare the performance of the existing conduits and the customized geometries.

RESULTS

In this study, a methodology for patient-specific analysis of RV-PA conduit in silico was developed. The results of simulations for 10 patients showed between 23% and 56% decrease in the average wall shear stress and between 24% and 87% reduction in average power requirements in customized designs compared with the stenosed conduits, translating into better hemodynamic performance.

CONCLUSIONS

Creation of an optimal conduit for an individual patient can be achieved using surgeon-guided design and computational fluid dynamics analysis. Manufacture of personalized RV-PA conduits may obviate the need for surgical customization to accommodate existing materials and provide superior long-term outcomes.

Для цитирования: Ebrahimi Pegah, Youssef David, Salve Gananjay, Ayer Julian, Dehghani Fariba, Fletcher David F, Winlaw David S. Evaluation of personalized right ventricle to pulmonary artery conduits using in silico design and computational analysis of flow.. JTCVS open. 2020. DOI: 10.1016/j.xjon.2020.02.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.