Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
Evaluation of the Efficacy of Transcatheter Aortic Valve Replacement in Asymptomatic Patients With Severe Aortic Stenosis Using Cardiopulmonary Exercise Testing.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chang Ya, Li Liu, Ma Yinshan, Zhou Jie, Wang Le, Zhan Yinge
Аннотация
BACKGROUND: The management of asymptomatic patients with severe aortic stenosis (AS) remains challenging. While transcatheter aortic valve replacement (TAVR) is established for symptomatic AS, its objective functional benefits in asymptomatic individuals are not well-defined.
AIMS: To evaluate the safety and hemodynamic efficacy of TAVR in asymptomatic patients with severe aortic stenosis and to objectively quantify their functional recovery using cardiopulmonary exercise testing (CPET).
METHODS: In this single-center retrospective study, 156 asymptomatic patients with severe AS undergoing TAVR with the VitaFlow valve were enrolled. Safety endpoints were adjudicated per Valve Academic Research Consortium (VARC-3) criteria. Efficacy was assessed via serial echocardiography and brain natriuretic peptide (BNP) levels at baseline, 1 day, 7 days, 3 months, and 12 months. Functional capacity was objectively quantified using CPET at baseline, 1 month, and 12 months.
RESULTS: Procedural success was 100% with no mortality, stroke, or major complications. Hemodynamics improved immediately (mean gradient: 51.6 ± 11.7 to 13.7 ± 7.2 mmHg, p < 0.001) and remained stable at 12 months. BNP levels decreased significantly from 7 days onward (p < 0.05). CPET revealed substantial improvements in functional capacity: peak oxygen uptake (VO₂) increased from 15.6 ± 3.6 to 19.8 ± 4.0 mL/kg/min (p < 0.001), anaerobic threshold (AT) increased, and ventilatory efficiency (VE/VCO₂ slope) decreased (all p < 0.001). The incidence of exercise-induced adverse events also significantly declined.
CONCLUSIONS: TAVR is a safe and highly effective intervention for asymptomatic severe AS, resulting in immediate hemodynamic improvement and sustained, objective enhancement of functional capacity, as rigorously quantified by CPET.
AIMS: To evaluate the safety and hemodynamic efficacy of TAVR in asymptomatic patients with severe aortic stenosis and to objectively quantify their functional recovery using cardiopulmonary exercise testing (CPET).
METHODS: In this single-center retrospective study, 156 asymptomatic patients with severe AS undergoing TAVR with the VitaFlow valve were enrolled. Safety endpoints were adjudicated per Valve Academic Research Consortium (VARC-3) criteria. Efficacy was assessed via serial echocardiography and brain natriuretic peptide (BNP) levels at baseline, 1 day, 7 days, 3 months, and 12 months. Functional capacity was objectively quantified using CPET at baseline, 1 month, and 12 months.
RESULTS: Procedural success was 100% with no mortality, stroke, or major complications. Hemodynamics improved immediately (mean gradient: 51.6 ± 11.7 to 13.7 ± 7.2 mmHg, p < 0.001) and remained stable at 12 months. BNP levels decreased significantly from 7 days onward (p < 0.05). CPET revealed substantial improvements in functional capacity: peak oxygen uptake (VO₂) increased from 15.6 ± 3.6 to 19.8 ± 4.0 mL/kg/min (p < 0.001), anaerobic threshold (AT) increased, and ventilatory efficiency (VE/VCO₂ slope) decreased (all p < 0.001). The incidence of exercise-induced adverse events also significantly declined.
CONCLUSIONS: TAVR is a safe and highly effective intervention for asymptomatic severe AS, resulting in immediate hemodynamic improvement and sustained, objective enhancement of functional capacity, as rigorously quantified by CPET.
Предметные рубрики MeSH
HumansAortic Valve StenosisFemaleRetrospective StudiesMaleTreatment OutcomeSeverity of Illness IndexExercise TestAged, 80 and overTime FactorsRecovery of FunctionHemodynamicsTranscatheter Aortic Valve ReplacementExercise ToleranceAgedPredictive Value of TestsAsymptomatic DiseasesAortic ValveBiomarkersHeart Valve ProsthesisNatriuretic Peptide, BrainFunctional StatusProsthesis DesignRisk Factors