Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures.
Аннотация
PURPOSE: The aim of this study was to biomechanically assess patellar tendon repair techniques with additional cable wire or polydioxanone suture (PDS) cord augmentation in comparison with a suture-anchor repair technique.
METHODS
Patellar tendon repair was performed in 60 specimens using a porcine bone model. Yield load, maximum load, stiffness and elongation of patellar tendon reconstructions with (1) cable wire augmentation, (2) PDS cord augmentation or (3) suture anchor repair were evaluated using a cyclic loading and load-to-failure test setup.
RESULTS
In comparison with suture anchor repair, augmentation of the reconstruction with either cable wires or PDS cords provides significantly higher maximum loads (527 and 460 N vs. 301 N; p < 0.01 and p = 0,012, respectively) under load-to-failure testing and less elongation (8.81 mm ± 1.55 mm and 10.56 mm ± 3.1 mm vs. 18.38 mm ± 7.51 mm; p = 0.037 and p = 0.033, respectively) under cyclic loading conditions.
CONCLUSION
Augmentation of a patellar tendon repair with either a cable wire or a PDS cord provides higher primary stability than suture anchor repair in patellar tendon ruptures. The study supports the use of additional augmentation of a tendon repair in the clinical setting in order to prevent loss of reduction and allow for early post-operative mobilisation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.