MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.202514507

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025

Real-Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors.

Wahl Dennis, Jaekel Finn, Henne Julia, Kantelberg Richard, Freund Daniel C, Grambow Eberhard, Vollmar Brigitte, Zitzmann Amelie R, Kleemann Hans, Hampe Jochen, Hinz Sebastian, Schafmayer Clemens, Leo Karl

СтатьяПеревод в очереди

Аннотация

Anastomotic failure remains one of the most severe complications in gastrointestinal surgery. Despite continuous advancements in stapler technologies and surgical techniques, it continues to be a leading cause of postoperative morbidity and mortality. It contributes substantially to prolonged hospitalization and increased healthcare expenditures. Currently, diagnosis is based on secondary systemic signs, such as inflammatory response or changes in drain fluid, followed by a multimodal diagnostic approach. However, reliable early detection of local alterations is still lacking. Here, the implantation of a bioresorbable is investigated, intra-anastomotically placed sensor device. By performing real-time intra-anastomotic bioimpedance measurements, ischemia-related changes are identified at an early, potentially reversible stage, prior to the onset of clinical or systemic manifestations. Furthermore, the sensor device offers the potential for future integration of pattern-recognition algorithms and the possibility of direct measurement of different markers in the anastomotic microenvironment.

Для цитирования: Wahl Dennis, Jaekel Finn, Henne Julia, Kantelberg Richard, Freund Daniel C, Grambow Eberhard, Vollmar Brigitte, Zitzmann Amelie R, Kleemann Hans, Hampe Jochen, Hinz Sebastian, Schafmayer Clemens, Leo Karl. Real-Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2025. DOI: 10.1002/advs.202514507.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.