Evaluation of 10°C as the optimal storage temperature for aspiration-injured donor lungs in a large animal transplant model.

Abdelnour-Berchtold Etienne, Ali Aadil, Baciu Cristina, Beroncal Erika L, Wang Aizhou, Hough Olivia, Kawashima Mitsuaki, Chen Manyin, Zhang Yu, Liu Mingyao, Waddell Tom, Andreazza Ana C, Keshavjee Shaf, Cypel Marcelo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Our recent work has challenged 4°C as an optimal lung preservation temperature by showing storage at 10°C to allow for the extension of preservation periods. Despite these findings, the impact of 10°C storage has not been evaluated in the setting of injured donor lungs.

METHODS

Aspiration injury was created through bronchoscopic delivery of gastric juice (pH: 1.8). Injured donor lungs (n = 5/group) were then procured and blindly randomized to storage at 4°C (on ice) or at 10°C (in a thermoelectric cooler) for 12 hours. A third group included immediate transplantation. A left lung transplant was performed thereafter followed by 4 hours of graft evaluation.

RESULTS

After transplantation, lungs stored at 10°C showed significantly better oxygenation when compared to 4°C group (343 ± 43 mm Hg vs 128 ± 76 mm Hg, p = 0.03). Active metabolism occurred during the 12 hours storage period at 10°C, producing cytoprotective metabolites within the graft. When compared to lungs undergoing immediate transplant, lungs preserved at 10°C tended to have lower peak airway pressures (p = 0.15) and higher dynamic lung compliances (p = 0.09). Circulating cell-free mitochondrial DNA within the recipient plasma was significantly lower for lungs stored at 10°C in comparison to those underwent immediate transplant (p = 0.048), alongside a tendency of lower levels of tissue apoptotic cell death (p = 0.075).

CONCLUSIONS

We demonstrate 10°C as a potentially superior storage temperature for injured donor lungs in a pig model when compared to the current clinical standard (4°C) and immediate transplantation. Continuing protective metabolism at 10°C for donor lungs may result in better transplant outcomes.

Для цитирования: Abdelnour-Berchtold Etienne, Ali Aadil, Baciu Cristina, Beroncal Erika L, Wang Aizhou, Hough Olivia, Kawashima Mitsuaki, Chen Manyin, Zhang Yu, Liu Mingyao, Waddell Tom, Andreazza Ana C, Keshavjee Shaf, Cypel Marcelo. Evaluation of 10°C as the optimal storage temperature for aspiration-injured donor lungs in a large animal transplant model.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2022. DOI: 10.1016/j.healun.2022.08.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.