DOI 10.1016/j.apmr.2025.08.015
Acoustic Measures of Voice Perturbation Offer Limited Value as Standalone Indicators of Laryngeal Penetration or Aspiration.
Аннотация
OBJECTIVE
To identify which, if any, acoustic measures are associated with swallowing safety.
DESIGN
Prospective, original research.
SETTING
Primarily outpatient.
PARTICIPANTS
A total of 34 adults (N=34) referred for a videofluoroscopic swallowing study (VFSS) were audio-recorded completing a sustained vowel and reading a sentence before the VFSS and again after swallowing each bolus.
INTERVENTIONS: Not applicable.
MAIN OUTCOME MEASURES: Swallowing safety was initially quantified using the Penetration-Aspiration Scale with ratings then defined dichotomously (eg, no penetration/aspiration vs penetration and/or aspiration). Acoustic measurements were calculated in Praat and included jitter (relative average perturbation [RAP]), shimmer (local), noise-to-harmonic ratio, and cepstral peak prominence (CPP).
RESULTS
Before bolus swallowing, RAP and shimmer (local) predicted penetration or aspiration (P=.036, P=.046, respectively) when included in a model with diagnosis and sex, whereas changes in CPP significantly predicted penetration or aspiration after bolus swallowing (P=.02) when included in a model with diagnosis and bolus consistency. However, receiver operating characteristic analyses were poor (P>.05), indicating these acoustic measures did not perform well as independent classifiers of airway invasion.
CONCLUSIONS
Although RAP, shimmer (local), and CPP may predict subsequent airway invasion in a larger model, they do not appear to be effective predictors when used alone. Noise-to-harmonic ratio was not predictive of penetration or aspiration in any of the models. Results suggest that acoustic voice features are insufficient as standalone indicators of airway invasion risk or events.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.